1-52 (No.RA073<Rev.001>)
13. NXDN
High
Deviation
[NXDN
Narrow]
<PC>
1) Adj item: [NXDN High Deviation
(NXDN Very Narrow)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
500
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
2995~3117Hz
<Panel>
1) Adj item: [Nn NDEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
[NXDN Very
Narrow]
<PC>
1) Adj item: [NXDN High Deviation
(NXDN Very Narrow)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
499
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
1311~1363Hz
<Panel>
1) Adj item: [Nv NDEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
14. QT
Deviation
[Analog Wide]
<PC>
1) Adj item: [QT Deviation (Analog
Wide)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
528
" for each
adjustment point.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
0.75kHz
±0.05kHz
<Panel>
1) Adj item: [Aw QT]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts