1-50 (No.RA073<Rev.001>)
6. Low
Transmit
Power
<PC>
1) Adj item: [Low Transmit Power]
2) Adj points: 5 points
[Low1], [Low3], [Center2],
[High1], [High3]
3) Press [Transmit] key.
Power meter
Ammeter
[
], [
]
25W
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
±1W
13A or less
<Panel>
1) Adj item: [L_POW]
2) Adj points: *Same as above
3) PTT : ON
[
], [
]
7. Ramp Up
Offset
<PC>
1) Adj item: [Ramp Up Offset]
2) Press [Transmit] key.
Power meter
Ammeter
[
], [
]
<PC>
[Automatic Adjustment]
1) Press [Tune Rump Offset] key.
2) Press [Apply] key to store the adjustment value
after the automatic adjustment has finished.
<PC> <Panel>
[Manual Adjustment]
1) Set the adjustment value to "1".
2) Press [Transmit] key for
<PC>
or [PTT] key for
<Panel>
and increase the adjustment value
slowly while monitoring the offset monitor value.
3) Set the adjustment value when the offset
monitor value exceed "65".
4) Press [Apply All] key for
<PC>
, or [ ] key for
<Panel>
to store the adjustment value.
<Panel>
1) Adj item: [RAMPU]
2) PTT: ON
[
], [
]
8. Ramp
Down Offset
<PC>
1) Adj item: [Ramp Down Offset]
2) Press [Transmit] key.
Power meter
Ammeter
[
], [
]
<PC>
[Automatic Adjustment]
1) Press [Tune Rump Offset] key.
2) Press [Apply] key to store the adjustment value
after the automatic adjustment has finished.
<PC> <Panel>
[Manual Adjustment]
1) Set the adjustment value to "1".
<Panel>
1) Adj item: [RAMPD]
2) PTT: ON
[
], [
]
9. Balance
<PC>
1) Adj item: [Balance]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
The Deviation of 20Hz frequency
is fixed.
Change the 2kHz adjustment
value to become the same
deviation of 20Hz within the
specified range.
<PC>
While pressing [Transmit] key,
click the check box "2kHz Sine
Wave" to change the 20Hz/2kHz.
Press [Apply] key to store the
adjustment value.
<Panel>
While PTT is ON, press the [
]
key to change the 20Hz/2kHz.
Press [ ] key to store the
adjustment value.
2kHz Tone
deviation is
within ± 1.0%
of 20Hz tone
deviation.
<Panel>
1) Adj item: [BAL]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method