(No.RA073<Rev.001>)1-37
*3
: When the mode is selected as P25, this function is enabled.
LED indicator
Red LED lights during transmission.
Green LED lights when there is carrier.
LCD display in panel test mode
4.2.3 Frequency and Signaling
The transceiver has been adjusted for the frequencies shown in
the following table. When required, readjust them following the
adjustment procedure to obtain the frequencies you want in
actual operation.
(1)Test frequency
[
]
Key/LCD check
The contents of the
pressed key etc.,
appear.
[ ]
High power/Medium
power/Low power
High: "H"
Medium: "M"
Low: "L"
[
]
Function off
-
[ ]
Compander on/off
On:
icon appears
[ ]
External Speaker on/off
On:
icon appears
[AUX
(Orange)]
Function off
-
[PTT]
Transmit
-
[0] to [9]
and
[#], [ ]
Function off
-
Key
Function
Display
(Power ON)
Type
Frequency range
136~174MHz
(After 2sec.)
Temperature
Power
An : Analog narrow mode
Aw : Analog wide mode
As : Analog wide 4k mode *4
P1 : P25 Phase1 mode
P2 : P25 Phase2 mode
Nn : NXDN narrow mode
Nv : NXDN very narrow mode
Squelch level
(Analog mode only)
Sub LCD display
Main LCD display
Signaling No.
Channel No.
*4: Wide 4k is displayed only when the PC test mode is used. However, it aims at production for
factory, or a operation verification of the transceiver. It is not necessary in operation of
the transceiver to adjust.
F type is
displayed as "K".
CH
RX (MHz)
TX (MHz)
1
155.05000
155.10000
2
136.05000
136.10000
3
173.95000
173.90000
4
155.00000
155.00000
5
155.20000
155.20000
6
155.40000
155.40000
7~16 -
-