1-40 (No.RA073<Rev.001>)
4.3.4 Adjustment item supplement
Adjustment Item
Description
Receive Assist
The lock voltage of VCO (Receive) is
adjusted.
This item must be adjusted before all
adjustment items for receiver section are
adjusted.
Transmit Assist
The lock voltage of VCO (Transmit) is
adjusted.
This item must be adjusted before all
adjustment items for transmitter section
are adjusted.
Frequency
Frequency is adjusted under receiving
condition with SSG.
The SSG needs 0.003ppm accuracy so
please use a standard oscillator if
necessary.
This item can be adjusted only in PC Test
Mode so that the adjustment value is not
changed easily.
Ramp Offset
Adjust this item to the optimal Ramp
voltage.
High Maximum
Power
High Maximum Power is adjusted.
Medium Maximum
Power
Medium Maximum Power is adjusted.
Low Maximum
Power
Low Maximum Power is adjusted.
High Transmit
Power
High Transmit Power is adjusted.
Medium Transmit
Power
Medium Transmit Power is adjusted.
Low Transmit
Power
Low Transmit Power is adjusted.
Balance
The transmit modulation frequency
response is adjusted.
This item is adjusted so that the deviation
of 2kHz becomes the same deviation of
20Hz.
This item must be adjusted before all
adjustment items for deviations are
adjusted.
High Deviation
(P25/NXDN)
High Deviation of P25/NXDN is adjusted.
Maximum Deviation
(Analog Wide/
Narrow)
Maximum Deviation of Analog (Wide/
Narrow) is adjusted.
This item must be adjusted before all
adjustment items for tone deviations are
adjusted.
QT Deviation
QT tone deviation is adjusted.
DQT Deviation
DQT tone deviation is adjusted.
LTR Deviation
LTR tone deviation is adjusted.
DTMF Deviation
DTMF tone deviation is adjusted.
Single Tone
Deviation
The deviation of Single Tone used in “2-
tone” is adjusted.
MSK Deviation
MSK tone deviation is adjusted.
CWID Deviation
CWID tone deviation is adjusted.
CWID is used to inform the others who is
transmitting on a 6.25kHz spacing
channel. (In FCC rule, Analog mode or
CWID is required for each channel-
spacing.)
Sensitivity 1
Band-Pass Filter is adjusted.
The performance of Receive Sensitivity is
improved.
Sensitivity 2
Band-Pass Filter is adjusted.
The performance of Receive Sensitivity is
improved.
RSSI Reference
The minimum RSSI level for scan stop is
adjusted.
Open Squelch
The squelch level at level “5” is adjusted.
Low RSSI
RSSI display level “
” is adjusted.
Both “Low RSSI” and “High RSSI” must be
adjusted. (The curve data of RSSI level is
applied.)
High RSSI
Tight Squelch
The squelch level at level “9” is adjusted.