1-40 (No.RA077<Rev.001>)
12. DQT
Deviation
*3
1) Adj item:
[DQT Deviation (Analog Wide)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 3kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
156
" for each
adjustment points.
0.75kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
1) Adj item:
[DQT Deviation (Analog Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 3kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
146
" for each
adjustment points.
0.35kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
13. DTMF
Deviation
*3
1) Adj item:
[DTMF Deviation (Analog Wide)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 15kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
156
" for each
adjustment points.
2.50kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
1) Adj item:
[DTMF Deviation (Analog Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 15kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
154
" for each
adjustment points.
1.25kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
14. Single
Tone
Deviation
*3
1) Adj item:
[Single Tone Deviation (Analog
Wide)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 15kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
738
" for each
adjustment points.
3.00kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
1) Adj item:
[Single Tone Deviation (Analog
Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) Deviation meter:
LPF: 15kHz/HPF: OFF
4) Press [Transmit] button.
Deviation meter
-ANT
Oscilloscope
FPU
[<],[>]
Write the reference
value "
729
" for each
adjustment points.
1.50kHz±0.05kHz
Press [OK] button to store the
adjustment value after all
adjustment points have been
adjusted.
NX-1300 Series (K4) type
Item
Condition
Measurement
Adjustment
Specifications/Remarks
PC tuning mode
Point
Method