(No.RA077<Rev.001>)1-31
7. Open
Squelch (5)
(DMR)
1) Adj item:
[Open Squelch (5) (DMR)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) SSG output: -123.5dBm (0.15uV) / No
modulation
SSG
-ANT
Distortion meter
Oscilloscope
-SP output
FPU
Input signal from SSG, press [Start] button
to adjust, and after that press [OK] button to
store the adjustment value.
8. Low RSSI
*5
1) Adj item:
[Low RSSI (Analog Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) SSG output: -120dBm (0.22uV)
MOD:1kHz/±1.5kHz
SSG
-ANT
Distortion meter
Oscilloscope
-SP output
FPU
Input signal from SSG, press [Start] button
to adjust, and after that press [OK] button to
store the adjustment value.
*5
: Because Low RSSI at -118dBm (Analog Wide, NXDN Narrow, NXDN Very Narrow and DMR) is adjusted by adjusting Low RSSI
at -120dBm (Analog Narrow), it is not necessary to adjust Low RSSI at -120dBm (Analog Wide, NXDN Narrow, NXDN Very
Narrow and DMR).
9. High RSSI
*6
1) Adj item:
[High RSSI (Analog Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) SSG output:-80dBm (22.4uV)
MOD:1kHz/±1.5kHz
SSG
-ANT
Distortion meter
Oscilloscope
-SP output
FPU
Input signal from SSG, press [Start] button
to adjust, and after that press [OK] button to
store the adjustment value.
*6
: Because High RSSI at -80dBm (Analog Wide, NXDN Narrow, NXDN Very Narrow and DMR) is adjusted by adjusting High RSSI
at -80dBm (Analog Narrow), it is not necessary to adjust High RSSI at -80dBm (Analog Wide, NXDN Narrow, NXDN Very Narrow
and DMR).
10. Squelch
(Tight)
1) Adj item:
[Tight Squelch (Analog Wide)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) SSG output: -116dBm (0.35uV)
MOD:1kHz/±1.5kHz
SSG
-ANT
Distortion meter
Oscilloscope
-SP output
FPU
Input signal from SSG, press [Start] button
to adjust, and after that press [OK] button to
store the adjustment value.
1) Adj item:
[Tight Squelch (Analog Narrow)]
2) Adj point: 5 points
[Low], [Low'], [Center], [High'], [High]
3) SSG output: -116dBm (0.35uV)
MOD:1kHz/±1.5kHz
SSG
-ANT
Distortion meter
Oscilloscope
-SP output
FPU
Input signal from SSG, press [Start] button
to adjust, and after that press [OK] button to
store the adjustment value.
NX-1200 Series (K) type
Item
Condition
Measurement
Adjustment
Specifications/
Remarks
PC tuning mode
Point
Method