NX-320
67
ADJUSTMENT (E TYPE)
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
7. DQT
Deviation
*4
[Narrow]
1) Adj item: [DQT]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
430 (Reference
value)
0.35kHz±0.05kHz
[Wide 4k]
1) Adj item: [DQT]
Adjust:
[
✳✳✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Wide 4k)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
0.60kHz±0.05kHz
[Wide 5k]
1) Adj item: [DQT]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Wide 5k)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
0.75kHz±0.05kHz
8. LTR
Deviation
*4
[Narrow]
1) Adj item: [LTR]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
465 (Reference
value)
0.75kHz±0.05kHz
[Wide]
1) Adj item: [LTR]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
1.00kHz±0.05kHz
9. DTMF
Deviation
*4
[Narrow]
1) Adj item: [DTMF]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
540 (Reference
value)