NX-320
66
ADJUSTMENT (E TYPE)
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
Maximum
Deviation
(Analog) *3
[Wide
5k]
1) Adj item: [ADEV]
Adjust:
[
✳✳
.
✳
.
✳
.]
2) Adj item: [A.DEV_]
→
[A.D.EV_]
→
[A.D.E.V_]
→
[A.D.E.V._]
→
[A.D.E.V._.]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Maximum
Deviation (Analog
Wide 5k)]
2) Adj item: [Low],
[Low’], [Center],
[High’], [High]
PTT:
Press
[Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
4200Hz
Write the value as
followings.
513 (Reference
value)
4150~4250Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
points have been
adjusted.
*3: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 70.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
6. QT
Deviation
*4
[Narrow]
1) Adj item: [QT]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [QT
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
513 (Reference
value)
0.35kHz±0.05kHz
[Wide 4k]
1) Adj item: [QT]
Adjust:
[
✳✳✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [QT Devia-
tion (Analog Wide
4k)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
0.60kHz±0.05kHz
[Wide 5k]
1) Adj item: [QT]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [QT Devia-
tion (Analog Wide
5k)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
0.75kHz±0.05kHz