NX-320
6
2. When the POWER is switched on, you can immediately
enter user mode. When the PC sends a command, the
transceiver enters PC mode, and “PROGRAM” is dis-
played on the LCD.
When data is transmitting from the transceiver, the red
LED lights.
When data is receiving by the transceiver, the green LED
lights.
Note:
The data stored in the computer must match the “Model
Name” when it is written into the fl ash memory.
5-3. KPG-22A description
(PC programming interface cable: Option)
The KPG-22A is required to interface the transceiver to
the computer. It has a circuit in its D-sub connector case
that converts the RS-232C logic level to the TTL level.
The KPG-22A connects the SP/MIC connector of the
transceiver to the RS-232C serial port of the computer.
5-4. KPG-22U description
(USB programming interface cable: Option)
The KPG-22U is a cable which connects to a USB port on
a computer.
When using the KPG-22U, install the supplied CD-ROM
(with driver software) in the computer. The KPG-22U driver
runs under Windows XP, Vista or 7.
5-5. KCT-53U description (USB adapter: Option)
The KCT-53U is a cable which connects the KPG-22A to a
USB port on a computer.
When using the KCT-53U, install the supplied CD-ROM
(with driver software) in the computer. The KCT-53U driver
runs under Windows 2000, XP or Vista (32-bit).
5-6. Programming software KPG-141D description
The KPG-141D is the programming software for the trans-
ceiver supplied on a CD-ROM. This software runs under
Windows XP, Vista or 7 on a PC.
The data can be input to or read from the transceiver and
edited on the screen. The programmed or edited data can
be printed out. It is also possible to tune the transceiver.
6. Firmware Programming Mode
6-1. Preface
Flash memory is mounted on the transceiver. This allows
the transceiver to be upgraded when new features are re-
leased in the future. (For details on how to obtain the fi rm-
ware, contact Customer Service.)
6-2. Connection procedure
Connect the transceiver to the personal computer using
the interface cable (KPG-22A/22U) and USB adapter (KCT-
53U: when the interface cable is KPG-22A, the KCT-53U can
be used.). (Connection is the same as in the PC Mode.)
6-3. Programming
1. Start up the firmware programming software (Fpro.exe
(ver. 6.0 or later)). The Fpro.exe exists in the KPG-141D
installed holder.
2. Set the communications speed (normally, 115200 bps)
and communications port in the confi guration item.
3. Set the fi rmware to be updated by File name item.
4. Press and hold the [Side1] key while turning the trans-
ceiver power ON. Then, the orange LED on the transceiv-
er lights and “FIRM PRG” is displayed.
5. Check the connection between the transceiver and the
personal computer, and make sure that the transceiver is
in the Program mode.
6. Press “write” button in the window. When the transceiv-
er starts to receive data, the [LOADING] display lights.
7. If writing ends successfully, the checksum is calculated
and a result is displayed.
8. If you want to continue programming other transceivers,
repeat steps 4 to 7.
6-4. Function
If you press the [Side1] key while “FIRM PRG” is dis-
played, the checksum is calculated, and a result is displayed.
If you press the [Side1] key again while the checksum is
displayed, “FIRM PRG” is redisplayed.
Note:
• This mode cannot be entered if the Firmware Program-
ming mode is set to Disable in the Programming soft-
ware.
• Normally, write in the high-speed mode.
• The text message are displayed for K2,K3,K5,K6,E and E2
models only.
7. Clone Mode
(K2,K3,K5,K6,E and E2 models only)
Programming data can be transferred from one transceiv-
er to another by connecting them via their external SP/MIC
connectors. The operation is as follows (the transmit trans-
ceiver is the source and the receive transceiver is a target).
The following data cannot be cloned.
• Tuning data
• Embedded message with password
• Model name data
• ESN (Electronic Serial Number) data
Note:
The following data can be cloned.
• Fleet (own)/ID (own) for FleetSync
• Unit ID (own) for NXDN
• ID (own) for MDC-1200
• My ID for 5-tone (E,E2 models only)
1. Press and hold the [
] key while turning the transceiver
power ON. If the Read authorization password is set to
the transceiver, the transceiver displays “CLN LOCK”.
If the password is not set, the transceiver displays
“CLONE”.
REALIGNMENT