ADJUSTMENT (K TYPE)
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
12. CW ID
Deviation
*4
[NXDN
Very
Narrow]
1) Adj item: [CWID]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
376 (Reference
value)
1.00kHz±0.10kHz
*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 50.
13. Battery
Warning
Level
writing
1) Adj item: [BATT]
Adjust:
[
✳✳✳
]
PTT:
ON
1) Adj item: [Battery
Warning Level]
PTT:
Press
[Transmit]
button.
Power meter
DVM
Panel
ANT
BATT
terminal
Press the PTT
switch or [Transmit]
button on the PC
window.
Apply 6.20V to
battery terminal.
Confi rm that one
pre-determined nu-
meric in the range 1
to 256 appears.
[Panel tuning mode]
Press [B] key to
store the adjust-
ment value.
[PC test mode]
Press [Apply] but-
ton to store the
adjustment value.
14. Battery
Warning
Level
check
[Panel test mode]
1) CH-Sig: 1-1
BATT
terminal
voltage: 6.0V while
transmitting
1) Test Channel
Channel: 1
Test
Signaling
Mode: Analog
Signaling: 1
BATT
terminal
voltage: 6.0V while
transmitting
Check
The transceiver
can transmit with
causing the LED to
blink.