![Kenwood KVT-719DVD Service Manual Download Page 33](http://html.mh-extra.com/html/kenwood/kvt-719dvd/kvt-719dvd_service-manual_187235033.webp)
33
KVT-719DVD/729DVD
/729DVDY/739DVD
2-3. Specifi cation of screens
This section describes the test mode functions available in
each screen.
2-3-1. Test Mode Main screen
This section describes the keys for transferring to each
screen from Test Mode Main screen.
The variety of screens displayed on Test Mode Main screen
is shown in Figure 2-3-1.
Figure 2-3-1 Test Mode Main screen
[Key specifi cation]
Information: Move on to Information screen.
Service: Move on to Service screen.
Source: Move on to Source Direct screen.
Set Up: Move on to Set Up Menu screen.
Audio: Move on to Audio Control Menu screen.
Touch: Move on to Touch Adjust screen.
HPOSI: Move on to HPOSI Adjust screen.
Auto Adjust: Move on to Auto Adjust Menu screen.
iPod: Move on to iPod Authentication Confi rmation screen.
Inverter: Move on to Inverter Confi rmation screen.
Tilt MECHA: Move on to Tilt MECHA Position Adjustment
screen. Only in “DDX” and “DNX” series
ExtSw Test: Ext-Sw waveform output (Output is “400ms
ON/OFF” using operations, SW1
→
SW2
→
SW3
→
SW4.)
Operation SW3/4 for “MID KOS”.
2-3-2. Information screen
This screen shows such data as Ser ial No., Version
information of each µ-com, Region code, Status, etc.
The contents displayed on the Information screen are shown
in Figure 2-3-2.
Test Mode Main
Information
Service
Source
Set Up
Audio
Touch
HPOSI
Auto Adjust
iPod
Inverter
Tilt MECHA
EXT SW TEST
Figure 2-3-2 Information screen
• Monitor µCom information is shown only when the “KOS
Monitor” is connected.
• B/E, F/E, Region, and macrovision information are shown
only for the “KVT/DDX/DNX” series.
• TV Tuner Box is shown only when the “TV” is connected
(“V500” is “V- - - -”).
• Version information of the “OSD-ROM” is shown at the left
of the OSD display of the iPod image.
• Display shown before System/Audio is Model: Mid/Low
and Type: KVT/DDX/DNX/KOS.
[Key specifi cation]
Return: Move on to Test Mode Main screen.
2-3-3. Service screen
This screen is used to display or clear service information.
Chroma data in the E2PROM is cleared. DC Offset detection
information is displayed or cleared.
The contents displayed on the Service screen are shown in
Figure 2-3-3.
Figure 2-3-3 Service screen
• “DVD Service INFO” and “DVD DivX Registration Code
Clear” are shown only for the “KVT/DDX/DNX” series.
Serial :
∗∗∗∗∗∗∗∗
DC Offset : None
Security : Off
Media Processor
Low KVT System µCom
Mid DDX Audio µCom
Monitor µCom
TV Tuner Box
Return
B/E : V
∗
.
∗∗
F/E : V
∗
.
∗∗
Region :
∗
macrovision : V
∗
.
∗∗
: Redboot 12:00:00 Sep 15 2006
Kernel Sep 15 12:00:00 JST 2006
RootFS 060915_12:00
: V
∗
.
∗∗∗
ROM : R– – – – Type
∗
: V
∗
.
∗∗∗
ROM : R– – – –
: V
∗
.
∗∗∗
ROM : R– – – Type
∗
: V
∗
.
∗∗∗
ROM : R– – – – Type
∗
Span
∗
Init
Return
Power On
∗∗∗
minutes
Monitor Open
∗∗∗
times
Monitor Close
∗∗∗
times
Serial
Clear
Chroma
Ready
DC Offset
None
Clear
Init
Init
∗
∗
∗
∗
■
Start
DVD Service INFO
Tuner Mute Level
DVD DivX
Registration Code Clear
TEST MODE