17
KDC-W4044UA/W4044UAY/W4044UG/W4044UGY
KDC-W413UA/W413UAY/W4544U/W4644UY
When replacing front-end (A1) of mother unit (X34-), or when
adding or replacing ROM correction (program correction
with ROM IC (IC10)), the following activities are required.
■
Overview
When replacing front-end (A1) in the model where ROM
correction and security data have been written into
E2PROM, included in the front-end (A1) pack, the transfer
function of the E2PROM data itself in the replaced front-end
(A1) is required.
This function in the above system configuration is used
to allow for complete replacement of the front-end at any
service center.
■
Overview of speci
fi
cations
Procedures for replacement are as follows: To install the
E2PROM to the mother unit (X34-), and replace front-end (A1)
with new front-end after copying the data in the E2PROM
(such as ROM correction data and other data) in the front-
end (A1) to the mother unit (X34-) by operating the system,
and then copy the data (such as ROM correction data and
other data) into the mother unit to the E2PROM of the front-
end (A1), operating the main body.
Tuner adjustment data was inserted during the tuner pack
manufacturing, and data will not be transferred because
front-end (A1) is built-in.
In addition, tuner adjustment data for new front-end (A1) is
supplied as a service part in which data was inserted.
■
Data to be copied
• ROM correction data
• Other data
Security
data
DEMO MODE ON/OFF status
POWER ON time (For maintenance)
Playback time (For maintenance)
EJECT count (For maintenance)
Panel open/close count (For maintenance)
CD I2C status (For maintenance)
CD offset error code (For maintenance)
CD sound skips count (For maintenance)
CD time code not updated count (For maintenance)
CD load switch errors count (For maintenance)
CD ejection errors count (For maintenance)
DC offset error (For maintenance)
Forced Power OFF information (For maintenance)
Serial number (For maintenance)
E2PROM data check data (For internal check)
■
Operation procedure
Operation procedure is different depending on the
conditions. Proceed with the appropriate operation
procedure depending on the speci
fi
c condition.
1. In case of replacing front-end (A1) without an applicable
ROM correction.
2. In case of replacing front-end (A1) with an applicable
ROM correction.
3. In case of applying new ROM correction at the same time
when front-end (A1) is replaced. (No ROM correction has
been carried out.)
FRONT-
END (A1)
E2PROM
E2PROM
SYSTEM
μ
-COM (IC1)
Mother unit (X34-)
E2PROM circuit pattern
q
Install new E2PROM.
Install E2PROM containing no data, in case of [1] and [2].
In case of [3], install maintenance E2PROM with an
applicable ROM correction program.
FRONT-
END (A1)
E2PROM
E2PROM
SYSTEM
μ
-COM (IC1)
Mother unit (X34-)
w