14
KDC-W4044UA/W4044UAY/W4044UG/W4044UGY
KDC-W413UA/W413UAY/W4544U/W4644UY
About audio adjustment items (include both Audio Function Mode and Audio Setup Mode)
Procedure
Item
Procedure
Description
For item
forwarding
procedure,
press [AUD]
key and
[FM] key
Fader
[VOL] knob and [
/
] key
Adjust to 3 steps of R15
↔
0
↔
F15. (Default value: 0)
Balance
[VOL] knob and [
/
] key
Adjust to 3 steps of L15
↔
0
↔
R15. (Default value: 0)
Bass Level
[VOL] knob and [
/
] key
Adjust to 3 steps of -8
↔
0
↔
+8. (Default value 0)
Middle Level
[VOL] knob and [
/
] key
Adjust to 3 steps of -8
↔
0
↔
+8. (Default value 0)
Treble Level
[VOL] knob and [
/
] key
Adjust to 3 steps of -8
↔
0
↔
+8. (Default value 0)
LPF Sub woofer
[VOL] knob and [
/
] key
Adjust to 2 steps of 80Hz
↔
Through. (Default value: Through)
(Only in models with Sub Woofer output)
Volume Offset
[VOL] knob and [
/
] key
Adjust to 3 steps of -8
↔
0
↔
+8 (Default value: 0 and only in the
internal AUX model)
Procedure
Note
Press and hold [MENU] key
Switch Bass Boost (Note: Front key functions as MENU.)
■
[ATT] key operation
Procedure
Note
In the TUNER source, press [DISP] key
ATT OFF/ON
■
MENU-related test mode
Procedure
Note
Press the [MENU] key (main unit)
Press the [DNPP/SBF] and [DIRECT] keys (Remote control)
Continuous forwarding by remote control is prohibited
■
Backup current measurement
Procedure
Note
While ACC OFF (Back Up ON), Reset
MUTE terminal is OFF after 2 seconds, not after 15 seconds.
(During this time, the CD mechanism does not function.)
■
PREOUT switching
Procedure
Note
In the STANDBY source, press and hold [AUD] key for
1 second or longer
Switches PREOUT
■
Fluorescent indicator (ED1) short check
Procedure
Note
In the STANDBY source, press [AM] key
All lights are off
→
Turns on odd and even terminals alternatively every 125ms
(terminals that have a maximum number of grids)
→
Turns on only the odd
terminals
→
Turn on only the even terminals
→
■
Clearing CD mechanism information / Service information / DC offset error information (Clearing E2PROM data)
Status
Display
Description
While pressing and holding [2] key and
[5] key, reset-start.
C
L
R
O
At normal termination
C
L
R
X
At abnormal termination
TEST MODE