1. Product Introduction

 

2. Product Intended use

 

3. Contraindication and Adverse 

    Reaction

 

4. Primary Structure of Product

 

The Transcutaneous Electrical Nerve Stimulators  is a portable and battery 
powered multifunctional device. 
The Transcutaneous Electrical Nerve Stimulators  (model: KTR-2610) 
offering Transcutaneous Electronic Nerve Stimulator (TENS), Electronic 
Muscle Stimulator (EMS) and FITNESS. It has 50 operation modes, which 
can give certain electrical pulse through electrode pads placed on the skin 
to help users to enjoy body stimulation.
The electronic stimulatory module has the operating elements of ON/OFF 
Key, Display screen, Mode Selection key and Intensity Modification keys. 
The LCD display screen can show selected mode and program, output 
intensity, stimulate frequency, and time remaining of an application mode.
The device is equipped with accessories of electrode pads, electrode wires, 
and batteries. The electrode wire is used to connect the patches to the main 
unit. 
The electrode pads are complying with the biocompatibility standards ISO 
10993-5 (Cytotoxicity) and ISO 10993-10 (Irritation and Sensitization), are 
interchangeable.

3.1 Contraindication

a) The long-term effects of chronic electrical stimulation to the human body 
are not known.
b) Patients with cardiac pacemaker are disabled!
c) Patients with suspected or confirmed have epilepsy, heart disease, 
pregnancy or 
menstruating women are prohibited.
d) Treatment parts have the haemorrhage after acute trauma or fractures, 
disabling wound healing stage after the operation.
e) Treatment is not sensitive to heat or electrical stimulation of the skin 
patients disabled.
f) Disturbance of consciousness or disabled children.
g) Treatment of swelling, skin infection or with skin disease, phlebitis 
patients disabled.
h) With wet skin after shower, sweating and disabled when you go to sleep.
i) Driving traffic tools or disable during movement.
j) Metal allergies are disabled.

The Transcutaneous Electrical Nerve Stimulators  mainly consists 
of main unit, electrode patches and electrode wires. The primary structure 
of main unit as shown below:

3.2 Adverse Reaction

1) You may experience skin irritation and burns beneath the stimulation 
electrodes applied to your skin;
2) You may experience headache and other painful sensations during or 
following the application of electrical stimulation near your eyes and to your 
head and face;  
You should stop using the device and should consult with your physician if 
you experience adverse reactions from the device.

TENS (Mode 1~20) 
To be used for temporary relief of pain associated with sore and aching 
muscles in the shoulder, waist, back, back of the neck, arm, leg, and foot 
due to strain from exercise or normal household work activities by applying 
current to stimulate nerve.
EMS (Mode 21~40)
It is intended for relaxation of muscle spasm, prevention or retardation of 
disuse atrophy, increase local blood circulation, and muscle re-education.
FITNESS (Mode 41~50)
Improvement of abdominal tone, strengthening of the abdominal muscle 
development of firmer abdomen.

01

02

03

Summary of Contents for KTR-2610

Page 1: ...us free of charge but the costs for parts and components and transport will be undertaken by the purchaser However man made damages such as water enters inside the product product drops on the ground...

Page 2: ...03 5 Product Main Features 04 6 Product Requirements and Major Parametric Description 04 7 Method of application 06 8 Safety Precautions 07 9 Product maintenance 10 10 Product Scrap Processing 11 11 A...

Page 3: ...arts have the haemorrhage after acute trauma or fractures disabling wound healing stage after the operation e Treatment is not sensitive to heat or electrical stimulation of the skin patients disabled...

Page 4: ...2 years the use life of the small Electrode Pad is 80 times and shelf life is 2 years 6 3 Product Environmental Requirement a Normal work environmental requirements Environment temperature 5 40 Envir...

Page 5: ...ase intensity 5 Mode switch Short press F key to switch three major modes of TENS EMS and FITNESS 6 The adjustment of timing Long press F key for 1 5 seconds to set up the stimulation time of 15 minut...

Page 6: ...l parts including 3 AAA LR03 battery Prevent sharp parts from damaging the product Do not use accessories not specified by the manufacturer Please do not use in the parts which is nearest heart head e...

Page 7: ...o move the plugs in emergency circumstances Check the equipment before each use to avoid the exposed wires caused by accidental damages or other reasons Dust may affect the performance of the unit ple...

Page 8: ...ooms near active AF surgical equipment electrophysiology laboratories armored rooms or areas where short wave therapy equipment is used Do not use the system around strong electric filed electromagnet...

Page 9: ...ommunications equipment including peripherals such as antenna cables and external antennas should by used no closer than 30cm to any part of the ultrasound system including cables specified by the man...

Page 10: ...17 Hz 2 2 0 3 0 3 0 2 0 3 0 3 28 28 9 1720 1845 1970 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE 1 3 4 25 Band UMTS Pulse modulation 217 Hz 2 28 2450 2400 2570 Bluetooth WLAN 802 1 1 b g n RFID 245...

Reviews: