21
DRAIN ERROR
Is displayed?
Is the connector connected
to pump motor assembly
disconnected or
disassembled?
Reconnect or
repair
the connector.
Yes
Yes
Drain pump
Connection connector
No
Yes
When you press both
SPIN SPEED
button and
SOIL LEVEL
button
simultaneously, is the
water level frequency
below 26.0 kHz?
(Refer to 7-3)
Check the AIR
CHAMBER,
the tube
(clogged),
and press
switch
Is the coil of the drain
pump too high or low?
(resistance of the coil
is 10-20
Ω
)
(Refer to 9-4 Pump motor
assembly)
Replace the
DRAIN
PUMP
ASSEMBLY.
No
Yes
Is the voltage between
connectors out of range?
(BL1 pin1, pin3)
- After remove Terminal
Position Assurance (TPA)
of connector, check as
follows.
- And if you finish to measure
the valve, You should put
TPA as original form.
- Pump running : 120V±5%
- Stopped Motor/Pump : 0~1V Method
1. Press the Power button, while the
SPIN SPEED
button and
SOIL LEVEL
button is pressed
simultaneously.
2. Press Start/Pause button.
: 1 time
Pump slow-speed running
: 2 times
Pump mid-speed running
: 3 times
Pump high-speed running
: 4 times
Stop the Motor/Pump
[Note] Environmental check list
1) The drainage hose must not stay in a lower position.
2) The drainage hose must not be bent or
clogged in any way due to the surrounding
physical configuration.
3) The drainage hose must not get frozen at all times.
4) The drainage pump must not have any improper
substance or material inside that may cause
a machine breakdown.
Replace the
MAIN PWB
ASSEMBLY.
Yes
No