35 / 79
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury,
disconnect unit from power before servicing unless tests require power.
8. Operation and Functions
R-SENSOR
J1
R42
(31.4
㏀
)
R43
(2
㏀
)
R44
(2
㏀
)
J2
J2
-
cut
-
cut
J1
-
-
cut
cut
Temperature
compensation
0
℃
-1.5
℃
(-2.7 ºF)
0
℃
-3
℃
(-5.4 ºF)
Resistance
R42
R42+R43
R42
R42+R43+R44
31.4
㏀
(31.4+2)
㏀
31.4
㏀
(31.4+2+2)
㏀
□
R42 : R-SENSOR standard resistance in normal mode (31.4
㏀
)
□
In case temperature of refrigerator compartment is week or insufficient, take the following action.
J01
J02
8-11 Compensation of Refrigerator Sensor On/Off Temp
• Cut J2 to increase the standard resistance by 2
㏀
⇒
1.5
℃
down (2.7 ºF down)
• Cut J1 & J2 to increase the standard resistance by 4
㏀
⇒
3
℃
down (5.4ºF down)