28 / 79
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury,
disconnect unit from power before servicing unless tests require power.
8. Operation and Functions
8-3. Compressor, Fan & Damper
Output
Comp
C FAN
F FAN
R FAN
Icemaker
Room FAN
Pantry Damper
INPUT
Se
n
s
o
r
T
a
rg
e
t
T
e
m
p
Freezer
On/Off
On/Off
On/Off
-
-
-
Refrigerator
-
-
-
On/Off
-
-
Pantry Drawer
-
-
-
-
Open/Close
Ice Harvest Condition
& Step Valve Location
-
-
-
-
On/Off
-
F Door Open
-
-
-
-
-
-
R Door Open
-
-
-
-
-
-
Defrosting Mode
Off
Off
Off
Off
Off
Close
Showroom Mode
(Demo Mode)
Off
Off
On only
F Door Open
On only
R Door Open
On only
R Door Open
Open
F Accela Chill
On/Off
(Coldest Temp
for setting time)
On/Off
(Coldest Temp
for setting time)
On/Off
(Coldest Temp
for setting time)
-
-
-
R Accela Chill
-
-
-
On/Off
(Coldest Temp
for setting time)
-
Open/Close
Accela Ice
On
for setting time
(only ice making
condition)
-
-
-
On
for setting time
(only ice making
condition)
-
8-5. Forced Defrost Mode
□
The defrost mode starts with compressor work time, defrost sensor temp, any error mode, etc.
□
The defrosting return is done by F or R Defrost sensor.
■
Compressor will not restart within 6 min after the refrigerator is disconnected from power supply.
□
Fan voltage of control mode : Freezer 13V, Refrigerator 13V, Icemaker Room 13V, Condenser 13V
□
How to Start :
Preparation Work
INPUT
“Lock” Mode ON
Freezer
Temp
Refrigerator
Temp
+
□
How to Proceed and End: Same as normal defrost mode
8-4. Defrost Mode