MIX 04 (694 444 64)
Kendrion Kuhnke Automation GmbH
126
17 May 2021
Analogue interface configuration
– Analogue outputs
Object overview
Slot
Object
Subindex Explanation
AO0
01
Object to output the scaled analogue values as real
value.
AO1
02
AO2
03
AO3
04
AO0
01
Is assigned automatically via the plugged module
AO1
02
AO2
03
AO3
04
AO0
01
Is assigned automatically via the plugged module,
when using scaled output values the automatic
configuration in the slot must be adjusted.
AO1
02
AO2
03
AO3
04
AO0
01
Scaling of the analogue output values by specifying
interpolation points. To output the scaled values, add
object 0x7300 AOOutputPV the object to the
mapping
AO1
02
AO2
03
AO3
04
AO0
01
Object for output of the analogue output values as
real value, in V or mA, depending on the plugged
module
AO1
02
AO2
03
AO3
04
AO0
01
Object for output of the analogue output values as
integer value (raw value)
AO1
02
AO2
03
AO3
04