32
A7 MIG Welder
© Kemppi Oy 2017
1735
OPERA
TING M
ANU
AL
Welding parameters and functions
Figure 4.10 Memory channel editing
–
Welding parameters and functions view
In the
Welding parameters
view you can, depending on the selected welding process,
• set the min, max and initial values for
Wire feed speed
.
• set the min, max and initial values for
Fine tuning
or
Voltage
.
• set the value for the
Dynamics
and
Pulse current
.
• set the value manually or from the curve for
Double pulse amplitude
and
Double pulse frequency
.
In the
Welding functions
menu you can, depending on the selected welding process,
• select
Wise functions
on and off and set up their effectiveness.
• select
Hot start
option OFF, ALWAYS ON or USER SETS ON/OFF and set
Hot
start level
and
Hot start time
by using the sliders.
• select
Crater fill
option OFF, ALWAYS ON or USER SETS ON/OFF and set
Crater
fill step level
,
Crater fill end level
and
Crater fill
time by using the sliders.
• select
Creep start
option CURVE or SET VALUE and set
Creep start level
by
using the sliders.
• select
Start power level
by using the slider.
• select
Touch sense ignition
option OFF or ON
Welding settings – Welding system
Figure 4.11 Welding system settings view
In the
Welding system
view you can modify all settings related to the behavior and
function of the welding system.
In the
General settings
menu you can
• turn
Water cooling
ON, OFF and AUTO by clicking on the buttons.
• adjust
Welding cable length
by using the slider bar.
• select
Fine tuning calibration point
by using the slider bar.
• select
Arc voltage
measurement ON and OFF by clicking on the button.
In the
Wire feed settings
menu you can
• adjust
Wire feed motor current warning level
by using the slider bar.
• select
Wire feed end step
ON and OFF by using the buttons.
In the
Gas settings
menu you can
• select
Pre gas time
and
Post gas time
CURVE or SET VALUE and adjusting the