Final decommissioning from operation
8.3
Disassembly works shall be carried out with utmost care to avoid stirring up dust on
the MaxiFil Clean device and injury to unauthorized personnel. The work area should
be separated/marked. Dust that has risen shall immediately be extracted via vacuum
cleaner qualified under dust class "H"!
The filtration component shall be removed prior to commencing the disassembly
process. It is necessary to use personal protective equipment such as protective
clothing, gloves and breathing apparatus with fan, and others to avoid contact with
hazardous dust.
The working area should be cleaned after the MaxiFil Clean device has been
disassembled.
Prior to disassembly with subsequent disposal, the expert disposal of components
contaminated with welding fumes shall be approved and clarified with a regional
institution.