KEMPER MaxiFil Clean Instruction manual -
EN
Product number: 150 2512
- 65 -
Rev.: 03
Technical changes and errors reserved.
Status as of: 02/2016
Troubleshooting
7.3
Failure
Possible cause
Corrective actions
All fumes cannot
be collected.
The distance of the exhaust nozzle
from the welding point is too large.
Slide the exhaust
nozzle closer.
The clean air vent is covered.
Uncover the clean air
vent.
The horn sounds
The suction power is too low, the
throttling valve in the exhaust nozzle
is closed.
Fully open the control
valve in the exhaust
nozzle.
The filtration cartridge (109 0476)
is saturated.
Replace the filter
cartridge.
(KEMPER Service)
Dust leak on the
clean air side.
The filtration cartridge (109 0476)
is damaged.
Replace the filter
cartridge.
(KEMPER Service)
The protective
motor relay (F4)
was activated.
Clogged suction filter (motor
temperature too high)
Allow the device to cool
off and/or replace the
suction filter.
The device cannot
be started.
No voltage.
Call an electrician.
The maximum filling capacity of the
dust collection filter has been reached
Replace the dust
collection tank
The Start/Stop sensor is connected,
however, it does not recognize the
current (no welding under process
yet)
Start the welding
process.