Kelly KDHE High Efficient Series/PM Motor Controller User’s Manual
V 3.4
9
13- Reserved
14- GND: Signal return
Notes:
1. All RTN and GND pins are internally connected.
2. Two PWR pins, J1-1 and J2-1, are internally connected. It’s recommended to use J1-1
to supply peripherals like alarm and contactor. Twist peripheral wires with PWR is the
preferred for EMC.
3. Kelly Ammeter positive connect to 5V power supply of controller, negative to J1-2.
4. Switch to ground is active. Open switch is inactive.
Caution:
•
Do not apply power until you are certain the controller wiring is correct and has been
double checked. Wiring faults will damage the controller.
•
Ensure that the B- wiring is securely and properly connected before applying power.
•
The preferred connection of the system contactor or circuit breaker is in series with the B+
line.
•
All contactors or circuit breakers in the B+ line must have precharge resistors across their
contacts. Lack of even one of these precharge resistors may severely damage the controller
at switch-on.