Kelly KBS Brushless Motor Controller User’s Manual
V 4.1
15
Functional description: If enabled, the max output current will be limited to half at reversing.
Suggestion: Set according to the practical situation, factory default is Disable.
(6)ABS
Value range: Enable and Disable
Functional description: ABS function
Suggestion: This function is available for firmware version 0104 or later. Set according to the
practical situation, factory default is Disable.
(7)Motor Top Speed In Reverse
Value range: 20%~100%
Functional description: Limit max reverse speed of the motor.
Suggestion: This function is available for firmware version 0104 or later. Set according to the
practical situation, factory default is 100%.
4.4 Step 4
(1)Regeneration
Value range: Enable and Disable
Functional description: If enabled, the controller can do regen braking. It will recover mechanical
energy and charge back to battery.
Suggestion: Set according to the practical situation.
(2)Brake Switch Regen Mode
Value range: Enable and Disable
Functional description: If enabled, turn off throttle and turn on brake switch will start regen.
Suggestion: Set according to the practical situation.
(3) Releasing Throttle Regen Mode and Max Allowed Regen Current
Value range: 0~20%
Functional description: Set the max allowed regen current in releasing throttle regen mode.
Suggestion: Set according to the practical situation, factory default is 0.
(4)Max Allowed Regen Current In Brake Switch Regen Mode
Value range: 5%~50%
Functional description: Set the max allowed regen current in brake switch regen mode.
Suggestion: Set according to the practical situation, factory default is 20%.
(5)Max Regen Current
Value range: 20%~100%
Functional description: Max regen current with max signal from brake sensor.
Suggestion: Set according to the practical situation, factory default is 100%.
(6)Brake Sensor Type
Value range: No used, 3-wire resistive pot, hall active throttle.
Functional description: Set brake sensor type. Please choose “Not Used” if analog brake sensor
isn’t used. You have to turn on brake switch to start regen, then vary regen with the signal.
Suggestion: Set according to the practical situation, factory default is “Not Used”.
(7)Brake Sensor Starting Point
Value range: 0~40%
Functional description: Set brake sensor effective starting point