background image

Under Weighing Status 

Press[Set Print] 

 

                                                                                                                                                                                                                                                                                                                                                                                                                           
                                                                                                                                                                                       
 

1: Choose Communication Address 01

26 

2: Serial Communication Baud Rate( 0

4 ) stands for Baud Rates separately

600,1200,2400,4800,9600 

3: Serial Communication Mode( 0

1 ):0

—Continuous sending mode

No receive

1

—Command Response 

Mode 

3

OPERATION 

3.1

 TURN ON AND AUTO SET ZERO

 

1

After power connection and turning on, the indicator will perform self-check then go into 

weighing state.

 

2

If the system was found departure from the calibrate zero however still within the range of turn 

on auto zero range, it will set zero automatically

 

3.2 AUTO SET ZERO (Semi-auto set zero) 

1

Press the key of[Zero] to make the indictor show zero, when the zero signal will be on. 

2

If the displayed value departure from zero, however still within the range of set zero, the [ZERO] key can 

work, or else the [ZERO] will not function 
3

Only when the stable signal light is on, it can be done to set zero. 

3.3

 TARE 

1

This indicator supply 3 types of TARE operation

 

    Normal Tare

Under weighing state, when weight display is minus value and weighing is stable, you can 

press  [TARE]  key  to  set  the  tarred  weight  to  be  current  gross  weight.  At  this  time,  the 
indicator  “NET”  displays  to  be  “0”,  and  the  “NET”  symbol  light  will  be  on

Only  “NET” 

Symbol light is on can you operate “Tare”

 

Preset Tare

Under weighing display state, press the key of PRESET TARE, the indicator will display [P 

***.**], the displayed value now is present tare value.

 

If you want to sent a new tare value, press number key to input the value, then press [input] 
key to confirm. 

Transfer  tare  value  according  to  vehicle  no.

Under  weighing  display  state,  press  [VEHICLE  NO.]  key 

indicator display [o ***.**],    press number key to input the value, then press [TARE], then the 
indicator will transfer the storied tare value to use.

 

2

Under weighing display state, seriate TARE operation is a

vailable. When the tare value is “0” the symbol 

light will turn off 
3

When the indicator meet the terms of setting zero, press [set zero] key to set the indicator to zero, and net 

value symbol lights will be off. 

3.4 Time and Date set 

1. Under weighing display state, press DATE key, the date symbol light will turn on, indicator display present 
date. If the operation is correct, press [INPUT] key, or [WEIGH] key to exit; if operation is not correct, please 
use number key to input correct date, then press [ENTER] key,.   
2. Under weighing display state, press TIME key, the date symbol light will turn on, indicator displays present 
date and runs time. If the time is correct, then directly press[ENTER] key or [WEIGH] key to exit; if time is not 
correct, please use number key to input correct time, then press [ENTER] key,.   

3.5 Battery

 

1. 

For the external battery’s cable supplied by manufacturer, the red wire is connected to battery’s positive end, 

and the black wire is connected to battery’s negative end. Wrong connection will damage the indicator and 
battery. Please follow strictly! 
2. When only using battery to supply power, battery column in the right display window will display present 
electric quantity left. If all the 3 symbol lights are on, it means the battery is sufficient; If two are on, it means 
the battery is relatively enough; If only one symbol light is on, it means the battery is low When electric quantity 
is short, the user should prepare to charge. The battery will give an alarm when only about 5.5V is left. If the 
use continues to operate, the battery will be less and less, and it will automatically give alarm to the user to 
replace a new battery or use AC power supply. 
3. For the first time to use battery, the battery should be charged completely. If it is not be used for a long time, 
it should be charged for 20 hours every two months. Care should be taken to move or fit. Avoid serious 
vibration or furious impact, and prevent to have the battery damaged due to short circuit inside the battery. 

Display 

[

P000000

 

INPUT SET PASSPORT 

98+ [ENTER]

 

Display 

[

Adr **

 

Input

1

 

+  [Enter]

 

Display 

[

bt    *

 

Input

 

1

 

+  [Enter]

 

Display

 

[

tF    *

 

Input

 

0

 

+  [Enter]

 

Setting Complete 
Back to weighing Status

 

Summary of Contents for XK3118K9-R

Page 1: ...plug in or out when the indicator is in the electrify status to avoid the static electricity damaging the indicator or load cells Load cell and indicator are static sensitive devices so static proof...

Page 2: ...aced in a vibrating area full of dust and not in a sloppy environment Before connecting or disconnecting indicator and peripheral equipment powder supply of the indicator and other devices should be f...

Page 3: ...00K TM800 LQ 680K DS 300 and LQ 730K 630K 635K etc Data storage can be customized Vehicle No and Tare 200pcs Cargo No 100pcs Weighing Record 500 groups Power Supply AC AC110 220V 50 60Hz Accessorial p...

Page 4: ...No Description Code 8 Connect to ground GND 9 Current loop input OUT 10 Current loop output OUT 11 RS232 for remote display TX Indicator remote output cable and screen display must be connected correc...

Page 5: ...he indicator meet the terms of setting zero press set zero key to set the indicator to zero and net value symbol lights will be off 3 4 Time and Date set 1 Under weighing display state press DATE key...

Page 6: ...Operations Display Remarks 1 Press Print o Ask to input Vehicle No Press Print under weighing status 2 Press numeral key to input Vehicle No o 01234 Example 01234 3 Press Enter hn Ask to input Cargo...

Page 7: ...inted at the same time when print function is set effective 3 If print fails due to some reason such as printer trouble etc press re print after trouble shooting A complementary copy will be printed 4...

Page 8: ...ice weighing records we suggest to clear after it is completed Err 18 Weighing records are full Please clear the weighing records a s a p dt This notice will be appeared after Err18 It means the indic...

Page 9: ...f date The format is as follows No X Byte Contents and Notes 1 02 XON Start 2 or Symbol Bit 3 Weighing Data High Bit Weighing Data Weighing Data 8 Weighing Data Low Bit 9 Decimal Digit From Right to L...

Page 10: ...Every Frame is formed by 14 groups of data a Symbol or b h Tare Value 6 digit and one radix point Comman d D Net Weight Format Every Frame is formed by 14 groups of data a Symbol or b h Net Weight Va...

Page 11: ...ATE 08 08 08 TIME 20 14 56 VEHICLE No CARGO No GROSS 1580 kg TARE 80 kg DISCOUNT 10 NET 1350 kg REMARK Appendix 3 Example for Report Printing Format Daily Report 1 Data 08 08 08 Serial No Time Vehicle...

Page 12: ...Such as 11 hn 11 If former Cargo no then press Enter directly Cargo no is no need to change 5 Press Enter Print Print weight bill III Print Weight Bill Double Weighing Storing Mode i e Empty Cargo fi...

Page 13: ...no 3 Press Tare Minus the stored tare weight 4 Press Print o Required Cargo no 5 Press Enter hn Former Cargo no 6 Send New Cargo No Such as 11 hn 11 If same as former Cargo no press Enter directly No...

Page 14: ...00 00 choose Printing 2 Press 1 P00 00 01 3 Press Enter Print Print out 3 copies of current daily report 2 Print Passed Daily Report Steps Operation Display Instructions 1 Press Print Setting P00 00...

Page 15: ...tor 1pc 2 User Manual 1pc 3 Calibration Manual 1pc 4 Eligible Certificate 1pc 5 9 Pin D Type Connector Pin 1pc 6 9 Pin D Type Connector Plastic Cover 1pc 7 Fuse 0 5A 1pc 8 Two head AC cable 1pc 9 6V 1...