background image

E

2

PROM is changed for please input the former calibration setting and turn 

on the indicator or calibrate it again. 

4.5 

Connection Error Notice

 

Display 

Note 

Err    P 

Lack of paper, printer connection error or printer error. Please press any key 
to exit. Please add paper, reconnect the printer or change with a new printer

 

 

Appendix 1

.

Serial communication data mode 

All data are the ASCII code. Each frame data is formed by 10 digits. The first digit is starting digit, 
the  10

th

  digit  is  the  stopping  digit  and  the  8  digits  in  the  middle  are  the  data  digits.  The 

communication format is as follows: 
 
I.  Continuous Sending Mode: 
The  sending  date  is  the  current  weight  of  indicator  (Gross  weight  or  Net  weight).  Each  frame  is 
formed by 12 groups of date. The format is as follows: 

  No. X Byte 

Contents and Notes 

02(XON)                                    Start 

+ or -                                          Symbol Bit 

Weighing Data                            High Bit 

 

 

Weighing Data                               

 

 

 

Weighing Data                               

 

Weighing Data                              Low Bit                                             

Decimal  Digit                      From  Right  to  Left

0

4

                               

10 

XOR Checksum                          High Four Digit       

11 

XOR Checksum                          Low Four Digit     

12 

03(X0FF)                                      Over 

          XOR Checksum

2

3

……8

 

II. Instruction Mode: 

Indicator  output  the  corresponding  data  according  to  the  commands  released  by  the  PC. 
Whenever the PC release an instruction the indicator will output one frame of data accordingly. 
PC commands: 

No. X 

Byte 

Contents and Notes 

02(XON)                                    Start   

A

Z                                          Address Serial No. 

A

I          Command  A

Handshake        Command  B

Read 

Gross Weight      Command C

Read Tare 

Command D

Read Net Weight    Command E

Read Vehicle 

No.        Command F

Read Cargo No.       

Command  G

Clear  All  Record      Command  H:  Zero           

Command I

Tare off       

XOR Checksum                          High Four Digit       

XOR Checksum                          Low Four Digit     

03(X0FF)                                      Over 

 

  XOR Checksum 

2

3

……

n-1 

)

 

 
 
Indicator Output Contents                       

Summary of Contents for XK3118K9-R

Page 1: ...plug in or out when the indicator is in the electrify status to avoid the static electricity damaging the indicator or load cells Load cell and indicator are static sensitive devices so static proof...

Page 2: ...aced in a vibrating area full of dust and not in a sloppy environment Before connecting or disconnecting indicator and peripheral equipment powder supply of the indicator and other devices should be f...

Page 3: ...00K TM800 LQ 680K DS 300 and LQ 730K 630K 635K etc Data storage can be customized Vehicle No and Tare 200pcs Cargo No 100pcs Weighing Record 500 groups Power Supply AC AC110 220V 50 60Hz Accessorial p...

Page 4: ...No Description Code 8 Connect to ground GND 9 Current loop input OUT 10 Current loop output OUT 11 RS232 for remote display TX Indicator remote output cable and screen display must be connected correc...

Page 5: ...he indicator meet the terms of setting zero press set zero key to set the indicator to zero and net value symbol lights will be off 3 4 Time and Date set 1 Under weighing display state press DATE key...

Page 6: ...Operations Display Remarks 1 Press Print o Ask to input Vehicle No Press Print under weighing status 2 Press numeral key to input Vehicle No o 01234 Example 01234 3 Press Enter hn Ask to input Cargo...

Page 7: ...inted at the same time when print function is set effective 3 If print fails due to some reason such as printer trouble etc press re print after trouble shooting A complementary copy will be printed 4...

Page 8: ...ice weighing records we suggest to clear after it is completed Err 18 Weighing records are full Please clear the weighing records a s a p dt This notice will be appeared after Err18 It means the indic...

Page 9: ...f date The format is as follows No X Byte Contents and Notes 1 02 XON Start 2 or Symbol Bit 3 Weighing Data High Bit Weighing Data Weighing Data 8 Weighing Data Low Bit 9 Decimal Digit From Right to L...

Page 10: ...Every Frame is formed by 14 groups of data a Symbol or b h Tare Value 6 digit and one radix point Comman d D Net Weight Format Every Frame is formed by 14 groups of data a Symbol or b h Net Weight Va...

Page 11: ...ATE 08 08 08 TIME 20 14 56 VEHICLE No CARGO No GROSS 1580 kg TARE 80 kg DISCOUNT 10 NET 1350 kg REMARK Appendix 3 Example for Report Printing Format Daily Report 1 Data 08 08 08 Serial No Time Vehicle...

Page 12: ...Such as 11 hn 11 If former Cargo no then press Enter directly Cargo no is no need to change 5 Press Enter Print Print weight bill III Print Weight Bill Double Weighing Storing Mode i e Empty Cargo fi...

Page 13: ...no 3 Press Tare Minus the stored tare weight 4 Press Print o Required Cargo no 5 Press Enter hn Former Cargo no 6 Send New Cargo No Such as 11 hn 11 If same as former Cargo no press Enter directly No...

Page 14: ...00 00 choose Printing 2 Press 1 P00 00 01 3 Press Enter Print Print out 3 copies of current daily report 2 Print Passed Daily Report Steps Operation Display Instructions 1 Press Print Setting P00 00...

Page 15: ...tor 1pc 2 User Manual 1pc 3 Calibration Manual 1pc 4 Eligible Certificate 1pc 5 9 Pin D Type Connector Pin 1pc 6 9 Pin D Type Connector Plastic Cover 1pc 7 Fuse 0 5A 1pc 8 Two head AC cable 1pc 9 6V 1...