C l e a n i n g a n d d i s i n f e c t i o n o f a i r h o s e s
•
Isolate power supply to panel shower.
•
Remove the shroud covering the internal parts of the panel.
•
Remove air supply hose by gently easing hose off the air outlet adapter.
(1)
•
Remove 90° elbow connector by unscrewing ¾” Air nut and gently pulling apart.
(2)
•
Put aside all hose clips in a safe place.
•
Whilst wearing the correct safety equipment, dip hoses into a disinfectant solution so all the hoses are submerged.
•
Remove from solution and clean out hoses using a pipe cleaning brush.
•
Dip hoses into disinfectant solution and flush through, continue this until hoses are clean.
•
Once hoses are clean, flush hoses through with fresh water.
•
Shake out any excess water and wipe dry.
•
Replace air supply hose by gently inserting into air outlet adapter.
•
Replace 90 degrees elbow connector by gently inserting into hose, screwing ¾” Air nut onto shower head hose pipes.
•
Reinstate power supply to Control Hub and reinstall shroud cover onto panel.
•
Run shower for 2-3 minutes to dry any moisture in the hoses.
•
Check for air leaks from hose connections and adjust accordingly.
Warning!
!
During regular cleaning of the shower area, do not direct a water hose at the shower head while it is
functioning. Many household and industrial cleaning products contain mild abrasives and chemical
concentrates and should not be used on this product.
Maintenance
1.
2.