![kelda 93001000 Installation Manual Download Page 12](http://html1.mh-extra.com/html/kelda/93001000/93001000_installation-manual_3948091012.webp)
12
Factory Settings
Air volume
A i r o v e r r u n f u n c t i o n
The system has an air overrun function which allows the air to continue to operate for approximately 1 second after the
water flow stops. This function purges the water from the shower head, reducing the build up of lime-scale.
Your Kelda shower will have a different fan speed setting depending on what shower head and water flow rate your prod-
uct has. This will be set at the factory.
The hub will automatically adjust fan speed to match minor changes in flow rate which may result from changes in
water pressure.
However the fan speed can be manually changed if for example the flow regulator is changed to a different value or for
other site specific reasons.
Changing the fan speed (10 settings)
•
The fan settings are pre-set by the factory.
•
To change the fan speed settings, press speed DWN once, the number of LED flashes next to the button indicate
what fan speed setting the Control Hub is currently set at. (There are 10 speed settings: 1-10)
1.
Speed down button
2.
Speed up button
F a n o v e r h e a t p r o t e c t i o n
In the unlikely event of the fan overheating from being jammed with debris or being continuously run in a hot environment,
then a protection mode will be triggered with reduced fan speed and fast LED flash on Hub. The fan will return to normal
operation once debris is cleared or the temperature returns to operational level.
F a n Te s t F u n c t i o n
Press and hold both up and down fan speed buttons simultaneously to run the fan independently of full shower operation.
Ti m e D e l a y F e a t u r e
•
This is only if shower is being used with a digital push button or PIR control
•
The factory setting is set at
30 seconds (3 LED Flashes)
•
Press Timer DWN once, the number of LED flashes next to the button indicate what timer setting the Control Hub is
currently set at. (There are 5 timer settings: 10s,15s,30s,45s,60s)
3.
Timer up button
4.
Timer down button