![kelda 93001000 Installation Manual Download Page 15](http://html1.mh-extra.com/html/kelda/93001000/93001000_installation-manual_3948091015.webp)
15
Flex Head Timed Flow:93003000
Flex Head Timed Flow Thermostatic: 93004000
Fixed Head Timed Flow: 93001000
Fixed Head Timed Flow Thermostatic: 93002000
Instructions for dismantling and reassembling head for cleaning
1.
Remove the fascia plate screw cap with a small flat head screwdriver
(1)
.
2.
Remove centre screw using a posi-drive PZ2 screwdriver ensuring the fascia plate
(2)
and atomisation engine
(3)
are
held until screw removed.
3.
Slowly lower fascia plate and atomisation engine.
4.
Carefully detach the rubber hose from the water chamber
(4)
ensuring not to remove the hose from the other end.
5.
Carry out clean, de-scale and sanitisation of shower head components using industry standard cleaning products.
6.
To reassemble, follow steps in reverse. Take care to correctly align nozzles
(5)
.
1.
2.
3.
4.
1.
2.
3.
4.
5.
5.