35
DOC06820 Rev. A
SERVICE / REPAIR MANUAL
RUNNING FLOOR II
®
DX
8.
Remove the (4) lower cylinder barrel clamp bolts and the (2) lower cylinder barrel clamps.
9. The cylinder is very heavy! 84 lbs [38 kg] Two people or a hoist are needed! When ready, remove the
remaining (2) rod end bolts at each end of the cylinder and lower the cylinder out of the drive.
Cylinder Installation:
10.
Use two people or a hoist to lift the cylinder up into place and loosely install the (2) lower rod end bolts
at each end of the cylinder.
11. Use the Cylinder Installation Location Guide to verify that
the cylinder is positioned accurately and that the threaded
pad is mated appropriately with the upper threaded
cylinder barrel clamp.
12. Use anti-seize on the upper rod end bolts before threading
them into the aluminum nut bar by hand.
13.
Hand tighten all (4) bolts on each rod end then torque.
(See Bolt Torque Requirements)
14.
Install all (4) lower cylinder barrel clamp bolts, each with (2) piece Nordlock washers and hand tighten
first, then torque. (See Bolt torque Requirements)
15. Follow procedure for installing check valves at both ends of the cylinder.
16.
Run the floor and check for leaks.