16
DOC06820 Rev. A
SERVICE / REPAIR MANUAL
RUNNING FLOOR II
®
DX
5.1 Service Information
• Use hydraulic oil or Vaseline to lubricate seals. Do NOT use grease.
•
Do NOT use Teflon tape on any hydraulic components.
•
When welding on drive frame, ground specifically to what you are welding on, otherwise it can short
across component assemblies ruining seals and gaskets.
•
KEITH sells flow meters, pressure testers for troubleshooting and several tools to aid in rebuilding
components and drives.
•
Use the following chart for tightening tubes and fittings.
Sizes
Tubes
Swivel Nuts or Hoses
-12 JIC
2 FFWR
1-1/4 FFWR
-16 JIC
1-1/2 FFWR
1 FFWR
-12 ORFS
1/2 FFWR
1/2 FFWR
-16 ORFS
1/2 FFWR
1/2 FFWR
•
FFWR (Flats From Wrench Resistance)
•
JIC (Joint Industry Council, 37° flare seating surface)
•
ORFS (O-Ring Face Seal)