Operation
Slim Jim Idrocompresso User manual
page 16
Go to stand-by
You have to leave the operational window to go to stand-by. In stand-by the controller is in sleeping
mode and the machine does not operate. There are two stand-
by modes: “NO HEAT” and “ECO-
MODE
”. At “NO HEAT” there is no power to the heating elements and the boilers will (eventually) cool
down to room-
temperature. At “ECO-MODE” the boilers will cool down to a lower set temperature and
are then kept at that temperature. The cup-heater will not activate when the machine is at
“ECO-
MODE” or “NO HEAT”.
See “Barista menu” (page
onwards) on how to program the controller to automatically turn ON,
OFF and to ECO daily.
operational window
touch
menu window
touch
stand-by window
choose “NO HEAT”
or “ECO MODE”
touch
touch
no-heat window
“NO HEAT”: the
machine will cool
down
eco window
“ECO”: the machine
will settle at lower
set temperature
touch
touching the central
button at “NO HEAT” or “ECO” will
return the machine to operation (first window)
A machine set at ECO will also turn to normal operation when any of brew-levers or mix-water switch
is manipulated.
This “first manipulation” will not result in starting a mix-water dispense.
Performing a flush will not take the machine out of NO HEAT or ECO.
GROUP 1
93.4
GROUP 2
47.2
GROUP 3
93.2
STEAM
124.6
MENU
STAND
BY
EXTERNAL
SENSOR
CLEAN
PROGRAM
SETTINGS
13 : 57
NO
HEAT
ECO
MODE
EXIT
THURSDAY 13 : 57
TECH. ASSISTANCE
KEES VAN DER WESTEN
SLIM JIM
NO HEAT
THURSDAY
13 : 57
TECH. ASSISTANCE
KEES VAN DER WESTEN
SLIM JIM
ECO