![Kees van der Westen Slim Mirage User Manual Download Page 16](http://html1.mh-extra.com/html/kees-van-der-westen/slim-mirage/slim-mirage_user-manual_3885583016.webp)
Operation
Slim Jim Idrocompresso User manual
page 15
Control panel
Note!
Remnants of detergent may unexpectedly activate the capacitive screen. For that reason you should
use plain (warm) water and a soft cloth only to clean the plastic front panel.
The control panel of the Triplette and Duette are very similar and have a 5-
“button” capacitive touch
screen. When at operation, the display will show the temperatures in °C or °F without the temperature
unit. The reason for this is that not showing the unit allows the use of a bigger font for the temperature
values. The user will be aware of the local unit-setting and realise that normal brewing is at 88-95°C or
190-203°F. The centre-line will turn orange when the controller sends out a signal to heat.
operational window
Triplette with
temperature in °C
the controller sends
out a signal to heat
group 2 and the
steam boiler
operational window
Duette with
temperature in °F
the Duette does not
have a 3
rd
group
Change individual boiler to ECO and back
The factory set operational temperatures of the boilers are 93.0°C (coffee) and 125°C (steam) (199°F
and 257°F) respectively. 125°C is equivalent to approximately 1.35 bar steam overpressure.
Each boiler can be individually set to a lower ECO temperature (50°C, 122°F for the coffee boilers,
70°C, 158°F for the steam boiler). At the lower temperature setting up to 80% power is saved while the
boiler will still have a short heat-up time (appr. 8 minutes)
. In the “operational window” of the interface,
touch-hold the button (about 6 seconds) of the boiler that you want to change until the colour of the
button-frame changes to green and the temperature value is replaced with ECO. Touch-hold again
and the corresponding boiler will heat up to operational temperature again.
An individual group set at ECO will also turn to normal operation when the corresponding brew-lever is
manipulated.
When the steam boiler is set to ECO, using any of the groups to make a brew or pressing the mix-
water switch will turn the steam boiler back to normal operation.
operational window
touch-hold (6s)
the green frame and
word ECO indicate
that setpoint is ECO
touch-hold (6s)
or operate the lever
Note that in the example above group 2 is at 45.6°C at moment of switching to ECO. As the ECO
temperature of the coffee-boilers is 50°C, the boiler will continue to heat until 50°C is reached. The
centre line will thus be orange in this situation.
GROUP 1
93.4
GROUP 2
45.6
GROUP 3
93.2
STEAM
124.6
MENU
GROUP 1
200.1
GROUP 2
114.1
STEAM
256.3
MENU
GROUP 1
93.4
GROUP 2
45.6
GROUP 3
93.2
STEAM
124.6
MENU
GROUP 1
93.4
GROUP 2
ECO
GROUP 3
93.2
STEAM
124.6
MENU
GROUP 1
93.4
GROUP 2
47.2
GROUP 3
93.2
STEAM
124.6
MENU