background image

4.

 

It is now time to assemble the insert. 

Remove the box and the bottom plate from the 

firebox. If you want to disassemble the body and the 

front-door, open the door/doors max and unscrew 

the four bolts (see ill). Carefully pull the front towards 

you. (App weight of front and door mod 2001, 35 kg) 

Important! The door/doors are not to be removed 

from the front.

5. Put the insert in place (so that it touches the smoke 

oulet pipe) and adjust the insert to a level position with 

the adjustable feet. The rear two feet are adjusted 

inside the firebox and the two in the front are adjusted 

from below the insert.

Tip! Put a magnetic spirit-level on the grinded surface 

on the inside of the door. This is very important to en-

able the automatic closing and locking of the door.

Grab the smoke outlet pipe by the protective iron 

rod and pull it into position enabling you to fit the two 

screws. 

Once again, check that the insert is level.

6.If nessesary assemble the front/door to the insert 

body. Be very careful to fit the screws firmly.

7. Fit the fireplace. Start with the bottom plate and the 

you assemble the vermiculite kit in the following order,  

1. Back, 2. Rear Left, 3. Top, 4. Rear right (now you 

have to gently push the top piece upwards) 5. For

-

ward left, 6. Forward right . The pieces must aligne 

with the inside sleeve on the bottom plate. 

Finish the installation by placing the log stopper on the 

front of the bottom plate.

8. If the open fireplace is narrow you can improve the 

cirkulation by making a hole in the lintel of the open 

fireplace. This hole is accomplished with a powerdrill.

The hole can be decorated by a Keddy hot air grill.

(Accessory)

If you want to cover the space between the insert and 

the original fireplace you can fit Keddys decorative 

frame for wall connection and guard. (Accessories)

- 7 -

Summary of Contents for SK1000

Page 1: ...Fireplace inserts Installation instructions Care and firing instructions Model SK1000 SK2000...

Page 2: ...MATION 3 IMPORTANT POINTS 3 PRECONDITIONS 4 Building notice Flue Combustion air Standard delivery Exploded diagram PREPARATIONS 5 INSTALLATION INSTRUCTIONS 6 8 CARE FIRING INSTRUCTIONS 9 10 TECHNICAL...

Page 3: ...been manufactured in accordance with the documents that form the basis for the respective certificates and their associated requirements for production inspections IMPORTANT POINTS Contact the Plannin...

Page 4: ...occur in houses with mechanical ventilation This is not normally necessary for a fireplace insert as it is installed in an existing open fireplace which is designed to work in the house atmosphere A...

Page 5: ...l installations of Keddy s fire place inserts with this parameter fulfilled Since existing open fireplaces vary in design this should be considered as an installation guide and we will discuss two ins...

Page 6: ...sory adjust the support leg to 90 degrees and screw it in alignment with the underside of the pipes Move the protection rod from the 45 degree smoke outlet to the 90 degree smoke outlet 3 Use the supp...

Page 7: ...e protective iron rod and pull it into position enabling you to fit the two screws Once again check that the insert is level 6 If nessesary assemble the front door to the insert body Be very careful t...

Page 8: ...you want to insulate it against the existing chimney with mineral wool Ensure that the insulation seals tightly against the existing chimney and that it is level with the upper edge of the pipe so no...

Page 9: ...RE FIRING WHEN THE FIREPLACE IN SERT IS NEW During the first week firing can be started carefully Begin with one or two fires a day with half of the fol lowing prescribed amount of wood A particular s...

Page 10: ...te the downdraught and avoid the nuisance of smoke enter ing the room in the initial stage If the premises are equipped with mechanical venti lation i e if there are one or more fans to evacuate the a...

Page 11: ...00 Height 470 475 mm Width 500 mm Depth 400 mm Weight 100 kg Flue pipe diameter 125 mm Efficency 82 Output 4 9 kw SK2000 Height 535 540 mm Width 600 mm Depth 500 mm Weight 125 kg Flue pipe diameter 12...

Page 12: ...www keddy se Keddy AB Box 542 441 15 ALINGS S Tel 46 0 322 781 80 Fax 46 0 322 781 89 E mail info keddy se Website www keddy se Rev 1 01 09 2013...

Reviews: