background image

 

1.Decide where the mineral woll sealing is to be 

pplaced in the chimney. If nessecery, clean the inside 

of the stove from soot or any loose mortar using a 

steelbrush.

 Measure the distance from the connection hole in 

the insert to the sealing point in the existing chimney.

Apply the mineral wool immediaetly under the top 

sleeve of the steel pipe with steelwire. Push the pres

-

sure ring on to the pipe so that it just makes contact 

with the mineral wool.

2. Assemble the pipes needed to reach the wool 

sealing point with heat resistant sealant to ensure no 

leaks in the joints. 

In the case of a 45 degree smoke outlet (standard) 

adjust the support leg to 45 degree angle and screw 

it to the pipes 60 mm from the lower end of the pipes. 

In case of a 90 degree smoke outlet (Accessory) 

adjust the support leg to 90 degrees and screw it in 

alignment with the underside of the pipes. Move the 

protection rod from the 45 degree smoke outlet to the 

90 degree smoke outlet.

3. Use the supportleg to insert the pipes into the fire

-

place. Push the pressure ring upwards to expand the 

insulation against the chimney walls.

Ensure that the insulation seals tightly against 

the chimney walls to prevent heatloss through 

the chimney. If nessesary add mineral woll insula

-

tion achieve a tight seal.

Important! Do not fix the pipes with putty or any 

kind of mortar as this can cause cracks to the 

chimney.

Apply the combustion air pipe to the steel pipes with 

sealent.

INSTALLATION GUIDE ALT. 1

- 6 -

In order to follow installation guide 1 the assesorie ”installation kit” is needed. If you find that the 

insert is to heavy to transport to the installation site it is easy to disassemble the body from the front/

door section of the insert. This is described later in the manual.

Summary of Contents for SK1000

Page 1: ...Fireplace inserts Installation instructions Care and firing instructions Model SK1000 SK2000...

Page 2: ...MATION 3 IMPORTANT POINTS 3 PRECONDITIONS 4 Building notice Flue Combustion air Standard delivery Exploded diagram PREPARATIONS 5 INSTALLATION INSTRUCTIONS 6 8 CARE FIRING INSTRUCTIONS 9 10 TECHNICAL...

Page 3: ...been manufactured in accordance with the documents that form the basis for the respective certificates and their associated requirements for production inspections IMPORTANT POINTS Contact the Plannin...

Page 4: ...occur in houses with mechanical ventilation This is not normally necessary for a fireplace insert as it is installed in an existing open fireplace which is designed to work in the house atmosphere A...

Page 5: ...l installations of Keddy s fire place inserts with this parameter fulfilled Since existing open fireplaces vary in design this should be considered as an installation guide and we will discuss two ins...

Page 6: ...sory adjust the support leg to 90 degrees and screw it in alignment with the underside of the pipes Move the protection rod from the 45 degree smoke outlet to the 90 degree smoke outlet 3 Use the supp...

Page 7: ...e protective iron rod and pull it into position enabling you to fit the two screws Once again check that the insert is level 6 If nessesary assemble the front door to the insert body Be very careful t...

Page 8: ...you want to insulate it against the existing chimney with mineral wool Ensure that the insulation seals tightly against the existing chimney and that it is level with the upper edge of the pipe so no...

Page 9: ...RE FIRING WHEN THE FIREPLACE IN SERT IS NEW During the first week firing can be started carefully Begin with one or two fires a day with half of the fol lowing prescribed amount of wood A particular s...

Page 10: ...te the downdraught and avoid the nuisance of smoke enter ing the room in the initial stage If the premises are equipped with mechanical venti lation i e if there are one or more fans to evacuate the a...

Page 11: ...00 Height 470 475 mm Width 500 mm Depth 400 mm Weight 100 kg Flue pipe diameter 125 mm Efficency 82 Output 4 9 kw SK2000 Height 535 540 mm Width 600 mm Depth 500 mm Weight 125 kg Flue pipe diameter 12...

Page 12: ...www keddy se Keddy AB Box 542 441 15 ALINGS S Tel 46 0 322 781 80 Fax 46 0 322 781 89 E mail info keddy se Website www keddy se Rev 1 01 09 2013...

Reviews: