4.4.5.1 Assignment of the terminal block X2A AIC module
Digital inputs and outputs
Function
Default setting
Term.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Term. Function
Digital input DI 4 Reset, unchangeable
16
15
0 V
Digital input DI 3
Prog. error,
unchangeable
14
13
0V
Digital input DI 2
Release AIC / Reset,
unchangeable
12
11
0V
Digital input DI 1 Precharging complet-
ed, unchangeable
10
9
0V
Digital output DO 4
Not preset
8
7
0V
Digital output DO 3
Not preset
6
5
0V
Digital output DO 2
Ready for operation,
changeable
4
3
0V
Digital output DO 1
Start pre-charge,
unchangeable
2
1
0V
Figure 36: Assignment of the terminal block X2A AIC module
4.4.5.2 Assignment of the terminal block X2A charging module
Digital inputs and outputs
Function
Default setting
Term.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Term. Function
Digital input DI 4
Not preset
16
15
24 V/<0.7 Adc
Digital input DI 3
Not preset
14
13
24 V/<0.7 Adc
Digital input DI 2
Not preset
12
11
24 V/<0.7 Adc
Digital input DI 1
Start precharging,
unchangeable
10
9
24 V/<0.7 Adc
Digital output DO 4
Not preset
8
7
0V
Digital output DO 3
Not preset
6
5
0V
Digital output DO 2
Supply failure,
unchangeable
4
3
0V
Digital output DO 1
Precharging complet-
ed (main contactor
active),
unchangeable
2
1
0V
Figure 37: Assignment of the terminal block X2A charging module