
4.3.4
Connection of filter, AIC, charging module and control at DC bus
N
L3
L2
L1
L3
L2
L1
C-in
C-out
F-in
F-out
F-T1
F-T2
C2 C1
①
ϑ
PB
PA
R-T1
R-T2
④
⑦
⑧
⑩
⑫
U V W
24Vdc
DC-Bus
⑨
M
Error
Error
U V W
L3 L2 L1
ϑ
+
KTY84
⑤
EtherCAT
⑪
U V W
②
24Vdc
0Vdc
A
A1
A2
PE
EtherCAT
EtherCAT
DI1
EtherCAT
DO1
DO1
DI3
DO2
DI2 24V ST
DI1
DO2
③
24Vdc
DC-Bus
L3
L2
L1
⑥
b
⑥
a
⑥
c
Legend
1
Main fuses
2
Main switch S1
3
Pre-charging fuses
4
Braking resistor with temperature switch
5
AIC filter with fan and temperature monitoring/switch-off
6
Mains contactor K1 with protective circuit
7
Charging module
8
AIC module
9
Axis module
10
24V power supply module with superior control
11 Motor
12 Decoupling relay with protective circuit (the decoupling relay is not required, if ensured that the load capac-
itiy of the relais contact is not exceeding).
Figure 30: Connection of filter, AIC and charging module
The connection lines between AIC and filter are partly unshielded and must be
laid at a distance of 15 cm from other cables. =>
„EMC-compatible installation“.
56
CONNECTION OF THE POWER UNIT
Summary of Contents for COMBIVERT H6 Series
Page 2: ......