DeVIce DATA OF THe 400 V DeVIceS
The values for the respective unit size are listed in the following tables.
Frequency-dependent maximum current
Device size
21
rated switching frequency
8 kHz
Output frequency
f
out
/ Hz
0
1.5
3
6
10
25
Frequency-dependent maximum current @
f
S
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim
/ %
2 kHz
180 180 180 180 180 180
4 kHz
180 180 180 180 180 180
8 kHz
133 158 175 180 180 180
16 kHz
55
71
83
99
110 133
Frequency-dependent maximum current @
f
S
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim
/ %
1.75 kHz
180 180 180 180 180 180
3.5 kHz
180 180 180 180 180 180
7 kHz
150 175 180 180 180 180
14 kHz
71
89
101 118 132 159
Frequency-dependent maximum current @
f
S
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim
/ %
1.5 kHz
180 180 180 180 180 180
3 kHz
180 180 180 180 180 180
6 kHz
167 180 180 180 180 180
12 kHz
87
108 120 138 155 180
Frequency-dependent maximum current @
f
S
Basic Time Period = 100 µs (Parameter is22=3)
I
lim
/ %
1.25 kHz
180 180 180 180 180 180
2.5 kHz
180 180 180 180 180 180
5 kHz
180 180 180 180 180 180
10 kHz
110 133 147 168 180 180
Table 14:
Frequency-dependent maximum current for unit size 21