![KEB COMBIVERT F6 series Instructions For Use Manual Download Page 31](http://html.mh-extra.com/html/keb/combivert-f6-series/combivert-f6-series_instructions-for-use-manual_660366031.webp)
31
DeVIce DATA OF THe 400 V DeVIceS
3.2 Device data of the 400 V devices
3.2.1 Overview of the 400 V devices
The technical data are for 2/4-pole standard motors. With other pole numbers the drive
controller must be dimensioned onto the rated motor current. Contact KEB for special or
medium frequency motors.
Device size
21
22
23
24
Housing
6
Rated apparent output power
S
out
/ kVA
62
80
104
125
Max. rated motor power
1)
P
mot
/ kW
45
55
75
90
Rated input voltage
U
N
/ V
400 (UL: 480)
Input voltage range
U
in
/ V
280...550
Input phases
3
Mains frequency
f
N
/ Hz
50 / 60 ±2
Rated input current
@
U
N
=
400V
I
IN
/ A
99
126
158
189
Rated input current
@
U
N
=
480V
I
IN_UL
/ A
85
106
128
162
Insulation resistance
@
U
dc
= 500V
R
iso
/ MΩ
> 20
Output voltage
U
out
/ V
0...
U
in
Output frequency
2)
f
out
/ Hz
0...599
Output phases
3
Rated output current
@
U
N
=
400V
I
N
/ A
90
115
150
180
Rated output current
@
U
N
=
480V
I
N_UL
/ A
77
96
124
156
Rated output overload (60 s)
3) 4)
I
60s
/ %
150
Software current limit
3)
I
lim
/ %
150
Overcurrent
3)
I
OC
/ %
180
Rated switching frequency
f
SN
/ kHz
8
4
2
4
8
6)
2
4
7)
Max. switching frequency
5)
f
S_max
/ kHz
16
Power dissipation at rated opera-
tion
1)
P
D
/ W
1356
1194
1320
1650
2074
1580
1887
Overload current over time
1)
I
OL
/ %
=>
„3.2.3.1 Overload characteristic (OL)“
Maximum current 0Hz / 50Hz at
f
S
= 2 kHz
I
out_max
/ %
180 /
180
180 /
180
154 /
180
154 /
180
180 /
180
129 /
180
141 /
180
Maximum current 0Hz / 50Hz
at
f
S
= 4 kHz
I
out_max
/ %
180 /
180
157 /
180
121 /
180
121 /
180
173 /
180
101 /
180
112 /
180
Maximum current 0Hz / 50Hz at
f
S
= 8 kHz
I
out_max
/ %
133 /
180
104 /
180
80 /
157
79 /
180
120 /
180
66 /
151
74 /
174
continued on the next page
Summary of Contents for COMBIVERT F6 series
Page 2: ......