GB - 20
Terminals
2.6
Terminal strips of the power circuit
Observe input voltage, since 230 V and 400 V class possible
All terminal strips following the requirements of the EN 60947-7-1 (IEC 60947-7-1)
Name
Function
Cable cross-sections
Terminals No.
L1, N
1-phase mains connection
1
L1, L2, L3 3-phase mains connection
U, V, W
Motor connection
++, PB
Connection for braking resistor
++, – –
Connection for braking module,
Regenerative- and supply unit or as
DC voltage input
250…370 VDC (230 V class)
420…720 VDC (400 V class)
T1, T2
Connection for temperature sensor
2
PE connection
3
Connection for shielding/screening
shield
2.6.1 Permissible cable cross-sections and tightening torques of the terminals
No.
permissible cross-section flexible with wire-end fer
-
rule
Tightening torque
mm²
AWG
Nm
lb inch
min
max
min
max
1
0.25
1.5
24
10
0.6
5
2
0.14
1.5
26
14
0.6
5
3
Screw M4 for ring thimble
1.3
11
Summary of Contents for COMBIVERT F5