GB - 14
Technical Data of the 400 V Class
2.3
Technical data of the 400V class
Inverter size
07 09
10
12 13 14
Housing size
D
D
D
D
D
D
Phases
3
3
3
3
3
3
Output rated power
[kVA] 1.8 2.8
4.0
6.6 8.3 11
Max. rated motor power
[kW] 0.75 1.5
2.2
4.0 5.5 7.5
Output rated current
[A] 2.6 4.1
5.8
9.5 12 16.5
Max. short time current
1)
[A] 4.7 7.4
10.4
17 21.6 29.7
OC-tripping current
[A] 5.6 8.9
12.5
21 25.9 35.6
Input rated current
[A] 3.6
6
8
13 17 23
Max. permissible main fuse gG
7)
[A] 16 16
16
20 25 25
Rated switching frequency
[kHz] 16
8
4 8 16 8
4
2
Max. switching frequency
6)
[kHz] 16 16 16 16 16 16 16 16
Power loss at nominal operating
[W] 90 105
140 160 170
185 185 185
Power loss at DC supply
[W] 87 100
130 150 160
170 165 160
Standstill current at 4 kHz
2)
[A] 2.6 4.1 5.8 5.8 5.8 9.5 12 14.5
Standstill current at 8 kHz
2)
[A] 2.6 4.1 5.2 5.8 5.8 9.5 9.5 9.9
Standstill current at 16 kHz
2)
[A] 2.6 3.5 3.5 2.9 5.8 5.8 5.7 5.7
Min. frequency at continuous full load
[Hz] 6
6
6
6
6
6
Max. heat sink temperature
90 °C (194 °F)
Motor cable cross-section
3)
[mm²] 1.5 1.5
1.5
2.5
4
4
Min. braking resistor
4)
[Ω]
120 120
82
82 56 56
Max. braking current
4)
[A] 7.5 7.5
10
10 15 15
Overload characteristic
(see annex A)
Input rated voltage
5)
[V]
400 (UL: 480)
Input voltage range
[V]
305…528 ±0
Input voltage at DC operation
[V]
420…746 ±0
Mains frequency
[Hz]
50 / 60 ±2
permitted mains forms
TN, TT, IT8), ∆-mains9)
Output voltage
10)
[V]
3 x 0…Uin
Output frequency
11)
[Hz]
see control board
Max. motor line length shielded at 4 kHz
[m] 30 100
100
100 100 100
Max. motor line length shielded at 8 kHz
[m] 20 30
100
100 100 –
Max. motor line length shielded at 16 kHz
[m] 10 10
20
100 100 –
1) With regulated systems 5% are to be subtracted as overmodulation capacity
2) Max. current before the OL2 function triggers (not at F5 in operating mode v/f)
3) Recommended minimum cross section of the motor line for rated power and a cable length of upto 100 m
(copper)
4)
This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
5) At rated voltages > 460 V multiply the rated current with factor 0.86
6) With BASIC control board only 2 kHz, with COMPACT only 8 kHz, with F6-K only 8 kHz
7) Protection in accordance with UL see annex B
8)
Restrictions when using HF filters
9)
Phase conductor grounded mains are only permissible without HF filters
10) The voltage at the motor is dependent on the series-connected units and on the control method (see A.3)
11) The output frequency is to be limited in such way that 1/10 of the switching frequency is not exceeded
Summary of Contents for COMBIVERT F5