58
Programming Menu
The LCD keypad has different access levels that are password protected.
Different levels provide access to more parameters and give the read and
write privileges.
If you expect to see more parameters or need higher access to change
parameters, please contact KEB.
A user can change the password by:
• Parameter OS01 at
Home > Prog > Operator System > OS01
• Home > Prog (F3) > Pass (F2)
The following passwords are used to gain access levels:
User
Access Level Password
Typical Access*
KEB
R/W
All background parameters
OEM
R/W
479
Control Type
Motor Type
Input/Output Functions
Adjuster
R/W
119
Advanced motor, speed, & control
parameters
User
R/W
27
Basic Level with Write privileges
Basic
Read only
11
Diagnostics, Fault Logs
The password must be entered with the NUM method of adjustment
described in Section 3.7.1.
From the OEM level, parameters can be hidden in the Adjust, User, and
Basic access levels (ie. unused or OEM specific settings). Refer to Section
3.11 for additional information.
3.6.2. Setting the
Password