41
Control Circuit - STO
2.2.2. Terminal Strip
Connections (F5-K)
X2A - Control
Pin Function
Name
Description
1
Digital Common
0V
Reference potential for digital inputs/outputs
2
20 ...24V Input
V
in
Voltage input when an external 24VDC
supply is used
V = 24VDC +20%/-15%
I
MAX
= 1A
3
Digital Common
0V
Reference potential for digital inputs/outputs
4
24V-Output
V
out
Approx. 24V output (max. 100 mA load)
V = 24VDC
±
25%
I
MAX
(Pin 4 +32) = 100 mA
5
Prog. Input LI11
I8
See Pins 8-12
Inputs according to:
IEC61131-2 Type 1
“0” = -3...5VDC
“1” = 15...30VDC
Scan time <= 1ms
LI02 digital filter reduces
false trigger due to relay
chatter, filter time 10-100msec
(adjustable)
6
Drive Enable
I7
Enable/Disable; response time < 1ms;
Enable instantly turns off motor current
7
Prog. Input LI09
I6
When I1...16, I8 are assigned as speed
selection, I1>I2>...I8
When I1...I8 are assigned as direction
inputs, both cannot be signaled together
Inputs not used for speed selection can
be assigned special functions.
8
Prog. Input LI08
I5
9
Prog. Input LI05
I2
10
Prog. Input LI04
I1
11
Prog. Input LI07
I4
12
Prog. Input LI06
I3
13
Digital Out 2
O2
Programmable Output Lo10
Default = Deceleration Active
Short-circuit proof digital
24VDC outputs specified
according to IEC61131-2.
I
MAX
= 100mA per output
14
Digital Out 1
O1
Programmable Output Lo05
Default = At Speed
15
Digital Common
0V
Reference potential for digital inputs/outputs
16
+10V Output
CRF
Analog Supply Voltage for speed ref.
+10VDC, +5%, max. 4 mA
17
Analog Input 1-
AN1-
Pattern Speed Input
0... ± 10VDC (R
i
= 55k
Ω)
Resolution: 11Bit + sign
Scan time: 1 ms
18
Analog Input 1+
AN1+
19
Analog Input 2-
AN2-
Pre-torque Input
20
Analog Input 2-
AN2+
21
Analog Common
COM
Common for analog in- and outputs
V = 0...
±
10VDC (max. 11.5VDC)
I
MAX
= 10mA; R
i
= 100
Ω
Resolution: 11Bit + sign
22
Analog Output 1
ANOUT1 Analog output of the motor speed closed
loop, (open loop = calculated)
23
Analog Common
COM
Common for analog in- and outputs
24
Analog Output 2
ANOUT2 Analog output of the motor torque
0 ... 10VDC (0 ... 2xT
Rated(motor)
)
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Operation Manual Version 3 33 00F5LUM K333...