43
Control Circuit - STO
2.2.3. Digital Inputs
(F5-K)
12
11
6 8 10
5
4
3
7 9
Use of
internal
voltage supply
Use of
external
voltage supply
12
11
6 8 10
5
4
3
7 9
+
2.2.6. Relay Outputs
(F5-K)
262830
252729
R2
R1
In case of inductive loads on the
relay outputs, protective wiring must
be provided (e.g. RC or diode arc
suppression)
Specifications:
Voltage = max. 30VDC
I = 0.01 ... 1A
2.2.5. Digital Outputs
(F5-K)
Potentiometer
Voltage
Current
18
17
+
0…±20mA
4…20mA
2022
19
18
17 21
+
*)
0…±10Vdc
2022
19
18
17
16
15
21
*)
R = 0…3/5/10kΩ
2.2.4. Analog Inputs
(F5-K)
15
13
14
15
13
14
COM
I1
I2