
113
Operation Problems
Problem
Cause/Solution/Troubleshoot
Motor Draws High Current
Verify correct motor data.
For PM motors, verify the correct relationship between the Motor
Rated Speed, Motor Rated Frequency and the number of motor poles
(Diagnostic Screen #12). Refer to the text for further description.
Perform a Motor Learn if this has not already been completed.
For PM motors, verify the encoder/motor pole position is correct.
Make note of the present LE06 Encoder Pole Position value and re-
learn as needed. Refer to Encoder slippage/mounting (PM motors)
for additional information.
For PM motors, the encoder channel A/B phasing (LE03 Swap
Encoder Channels) must be correct and the encoder/rotor position
learned with the correct setting. The correct A/B phasing can be
determined by the LL07 Encoder Synchronization procedure.
For induction motors, set LC01 Control Mode to Open Loop V/Hz to de-
termine if the issue is due to encoder, encoder settings or speed control
settings.
For open loop induction motors, the Low Speed Torque Boost may need
to be decreased or increased.
Verify the brake picks and does not drag and that there are no
other mechanical issues preventing the motor from rotating freely.
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Operation Manual Version 3 33 00F5LUM K333...
Page 4: ......
Page 136: ...136 Notes...
Page 137: ...137...