1-800-KEATING
|
INCREDIBLE FRYING MACHINE™ - SERIES 2006
15
PROBLEM
PROBABLE CAUSE
SOLUTION
Spark module fl ashing
a. Steady OFF.
b. Steady ON.
c. 1 Flash.
d. 2 Flashes.
e. 3 Flashes.
f. 4 Flashes.
g. 5 Flashes.
a. NO Power or Control Hardware
Fault.
b. Power applied. Control Okay.
c. Flame sense (current trial only). Active
until fl ame sense on next trial.
d. Marginal fl ame between 1.5mkA
and 0.5mkA.
e. Ignition lockout; too many ignition
failures:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
f. Ignition lockout; too many fl ame
losses:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
g. Control hardware fault detected.
ORDERING PARTS
Parts may be ordered by calling 1-800-KEATING or your local Keating service company. You may also order on-line
at Keating’s part store, www.keatingofchicago.com
Refer to the Keating Gas Fryer Limited Warranty for complete service and ordering information.
The model/serial plate is attached to the inside of the front door. The serial and model numbers are necessary
when ordering.
WARNING AND OPERATING PLATES
All warning and operating plates on the Keating Incredible Frying Machine™ should be in place at all times.
If plates are damaged or lost, replace them immediately.