1-800-KEATING
|
INCREDIBLE FRYING MACHINE™ - SERIES 2006
B. Air Flow
1. To determine the proper gas/air mixture, look into
the viewing window for each burner, located just to
the left of each burner air hose where the hose is
connected to the burner assembly.
(See Figure 8)
.
• bright red/orange with proper mixture -
orange “glow” around burner tube.
• too much gas – orange “haze” around burner
tube (showing incomplete combustion)
• too little gas – blue at front of burner, or
totally blue
REQUIRED TEST THERMOSTAT
Multimeter (for testing continuity)
CHECKING CONTINUITY WITH THE MULTIMETER
1. Rotate the thermostat shaft until an audible click
is heard.
2. Rotate the thermostat shaft left and right ten
times causing the switch to click on and off ten
times, while using the Multimeter to verify continuity.
3. If the switch does not show continuity during all
ten trials, replace the thermostat.
Disassembling the thermostat will void the
ther-
mostat warranty.
1. Set compression ring onto capillary end of bulb
fi nger tight, 1/2" from end of capillary.
2. Insert new thermostat bulb through control panel
back.
3. Apply oil resistant fl exible sealant on to compres-
sion fi tting thread before installing fi tting into fryer
vessel.
4. Position bent portion of bulb against far right heat
transfer tube and install compression fi tting snugly
into fryer vessel.
5. Adjust bulb so at least 2" of bent portion of it is
next to heat transfer tube and tighten compression
nut onto compression fi tting for fryer 18 & up. The
end of thermostat bulb should touch the burner tube
for 14" fryers.
6. Refi ll fryer with oil to “fi ll level line”.
7. Start fryer, preheat and calibrate with
thermometer.
11
Remove the cover by loosening the screws to
gain access to the burner viewing windows.
(14 IFM shown).