keatingofchicago.com
14
PROBLEM
PROBABLE CAUSE
SOLUTION
Delayed ignition
a. Spark electrode gap is incorrect.
b. Gas pressure excessive (incoming or
manifold).
c. Spark module intermittent.
a. Set proper gap on electrode
(See detail on Page 27).
b. Set pressure to serial plate.
c. Replace spark module.
Fryer has poor recovery
a. Over-fi lling baskets.
b. Over-fi lling fryer with oil.
c. Thermostat bulb improperly placed.
d. Carbon coating on heat transfer tubes.
e. Low gas pressure or volume.
f. Ineffi cient burner combustion.
a. Don't over-fi ll baskets.
b. Fill fryer up to “Fill Level” line as oil
will expand when heated.
c. Adjust bulb position. See page 10 –
Thermostat Bulb Positioning.
d. Boil-out fryer. See page 8 – Cleaning
and Boil-out.
e. Contact a qualifi ed service person
to check gas pressure.
f. Adjust gas/air mixture. See page 10 –
Flame Adjustment.
Fryer overshoots temperature setting
a. Thermostat bulb improperly placed.
b. Thermostat out of calibration.
a. Adjust bulb position. See page 10 –
Thermostat Bulb Positioning.
b. Calibrate thermostat. See page 10 –
Calibration.
Oil in fryer vessel smokes
a. Oil has begun to break down.
b. High carbon content in oil.
c. Dirty fryer vessel.
d. Inferior grade of oil.
e. Fryer is overheating.
a. Replace oil.
b. Filter oil completely, replace if
necessary.
c. Boil-out fryer. See page 8 – Cleaning
and Boil-out.
d. Check with supplier for the grade of
oil you need for your cooking
applications.
e. Check calibration of thermostat (See
page 10) and replace if necessary.
Basket lift mechanism will not operate
a. Breaker tripped.
b. Connections are loose or electronic
timer is faulty.
c. Actuator defective.
a. Reset breaker located in rear of fryer,
or on bottom of control panel back
(Note Basket Lift circuit breaker is
labeled).
b. Make sure connections are tight.
Replace timer if faulty.
c. Replace actuator.
Basket-lift motor runs, but basket does
not move
a. Actuator is faulty.
a. Replace actuator.
Basket(s) rise prematurely
a. Electronic timer is faulty.
b. Basket lift relay is faulty.
a. Replace timer.
b. Replace relay.