background image

I INTRODUCTION

SAFETY
PRECAUTIONS

WARNING

THIS SYMBOL WARNS YOU THAT SERIOUS BURNS
OR OTHER INJURIES MAY RESULT IF SAFETY
INSTRUCTIONS ARE NOT FOLLOWED.

l

This service manual should be retained in a safe
place for future reference. The installation of your
new fryer must conform to local codes or in the
absence of local codes, with the current National
Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas
Installation Code CAN/CGA-B149.1 or Propane
Installation Code CAN/CGA-B149.2.

l

Your ventilation hood, when installed, must conform
to the current ANSI/NFPA 96 standard.

l

No frame or restriction shall be constructed around
the fryer that will restrict air movement into the
fryer’s combustion area or prevent proper
ventilation.

l

Keating fryers are designed to operate on the gas
fuel specified on the serial plate (attached to the
inside of the door of the fryer) and must not be
operated with another gas fuel. They cannot be
converted to another gas fuel by turning or engaging
a switch.

FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors and liquids in the
vicinity of this or any appliance.

You will post, in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained from your local gas
supplier. You may use the yellow stick-on label
temporarily until you receive the data from your local
gas supplier.

IMPORTANT: 

In the event a gas odor is detected, shut

down unit at main shut-off valve and contact the local
gas company or gas supplier for emergency service.

l

You must maintain this appliance free and clear from

combustibles.

l

You must maintain the following minimum

clearances from combustible and noncombustible
construction:

l

You must install this appliance at least 16 inches

away from any open flame.

l

Adequate clearance for servicing and proper

operation must be maintained. Your fryer is designed
to be serviced from the front.

l

Keating commercial fryers are intended for other
than household use.

l

ALWAYS instruct new employees on proper fryer
operation.

l

A fryer should be operated ONLY by properly trained
personnel.

l

ALWAYS turn fryer off each night.

l

ALWAYS disconnect fuel source before servicing.

l

NEVER leave a fryer unattended during operation.

l

NEVER move a fryer when full of hot oil.

l

NEVER introduce objects or liquids into fryer, while
operational, which are not designed or made for
cooking.

l

THIS FRYER MAY NOT BE ALTERED, MODIFIED
OR CHANGED IN ANY WAY. 

The State of California enacted the California Safe
drinking water and Toxic Enforcement Act of 1986,
(Prop. 65), which “prohibits any person in the course of
doing business from knowingly and intentionally
exposing any individual to a chemical known to the
State of California to cause cancer or reproductive
toxicity without first giving clear and reasonable
warning to such individuals.” The Governor’s Scientific
Advisory Panel added  carbon monoxide to the list of
hazardous chemicals known to cause reproductive
harm.

In order to establish full compliance with Proposition
65, we attached a yellow warning label to each gas
fired fryer manufactured by Keating of Chicago, Inc.

Carbon monoxide would not be present in
concentrations that would pose a “significant risk” to
the consumer when the equipment is installed,
operated and maintained as follows:

1

Clearances

Combustible 

Noncombustible

Construction

 Construction

Back

6” 

0”

Right Side

6”

0”

Left Side

6”

0”

Summary of Contents for INSTANT RECOVERY

Page 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 715 S 25th AVENUEl BELLWOOD ILLINOIS l 60104 l 1 800 KEATING...

Page 2: ...nce 9 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 10 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Page 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Page 4: ...s l You must maintain the following minimum clearances from combustible and noncombustible construction l You must install this appliance at least 16 inches away from any open flame l Adequate clearan...

Page 5: ...DEFECTS OR OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keat...

Page 6: ...rrent ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS RE...

Page 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Page 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Page 9: ...NG PROCEDURES n USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL n CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER...

Page 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Page 11: ...er to a secure area to prevent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNE...

Page 12: ...OR The BEEPER will BEEP 4 times If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more STEP 2 PRESS all 3 buttons in sequence left center...

Page 13: ...thermostat bulb positioning Keating s patented thermostat application is accurate within 2 F of the dial setting between 250 F 350 F This accuracy is attained only if the thermostat bulb is placed pro...

Page 14: ...r 14 fryers 6 Refill fryer with oil to fill level line 7 Start fryer preheat and calibrate with thermometer D Hi Limit Check The manual Hi Limit test button can be used to test the Hi Limit Control by...

Page 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Page 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Page 17: ...ILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIGHT 004142 1 1 2 2 2 3 9 RUNNER PILOT...

Page 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Page 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Page 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Page 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Page 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Page 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Page 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Page 25: ...the inside of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer...

Page 26: ...23...

Page 27: ...24...

Page 28: ......

Page 29: ...____________ DEALER ________________________________________________________________________________________________________________ DATE OF PURCHASE __________________________________________________...

Reviews: