background image

14

VI PARTS LISTS

ORDERING PARTS

Parts may be ordered by part number by calling Keating’s authorized distributor in your area.

Refer to the Keating Instant Recovery® Gas fryer Limited Warranty for complete service and ordering information.

The model/serial plate is located on the inside of the front door. The serial and model numbers are necessary when
ordering.

NOTE: 

On Drop-In fryers, the model/serial plate is attached to the top of the control panel.

WARNING AND OPERATING
PLATES

All warning and operating plates on the Keating Instant Recovery® Gas fryer should be in place at all times. If
plates are damaged or lost, replace them immediately.

GAS FRYER PARTS LIST (MODELS WITH UNI-POT) PAGES 15 – 16

ITEM

DESCRIPTION

MODELS

PART # 10x11

14

18

20

24

34x24

1

GAS VALVE, MILIVOLT

AA, CMG
NATURAL GAS

023625

1

1

1

1

PROPANE

023624

1

1

1

1

GAS VALVE, 120V

BB, TS
NATURAL GAS

004269

1

1

1

1

1

PROPANE

008123

1

1

1

1

1

TAN KNOB

AA, CMG

004803

1

1

1

1

PILOT OPERATING HANDLE

CMG

019426

1

1

3

3

BRACKET FOR PILOT

CMG

004804

1

1

OPERATING HANDLE W/SCREW

5

SCREW FOR KNOB

AA

004805

1

1

1

1

6

2

THERMOPILE

AA, CMG

022770

1

1

1

1

3

RUNNER PILOT TUBE ASSEMBLY*

CALL 1 - 800 / KEATING

1

1

1

1

1

1

4

CONSTANT PILOT ASSEMBLY

ALL

004259

1

1

1

1

1

1

5

CONSTANT PILOT VALVE

ALL

004266

1

1

1

1

1

1

6

RUNNER PILOT AIR SHUTTER

NIPPLE W/NUT

015747

1

1

2

2

2

3

CLIP

004090

1

1

2

2

2

3

7

RUNNER PILOT ORIFICE

CALL 1 - 800 / KEATING

1

1

2

2

2

3

8

RUNNER PILOT ORIFICE HOLDER

STRAIGHT

004142

1

1

2

2

2

3

9

RUNNER PILOT 90° ELBOW

(1/4” - 1/8”)

015746

1

1

2

2

2

2

10

RUNNER PILOT TEE

IN TUBING

006474

1

1

1

2

11

RUNNER PILOT SOLENOID ADAPTER

ALL

005743

1

1

1

1

1

1

12

ALUMINUM 1/4” TUBING 

(Specify length)

CALL 1 - 800 / KEATING

1

1

3

3

3

5

13

RADIANT, 3 - FINS

ALL FRYERS

000041

2

3

4

4

6

14

BURNER

ALL

004088

2

3

4

4

5

6

15

BURNER ORIFICE

CALL 1 - 800 / KEATING

2

3

4

4

5

6

16

BURNER HOLD DOWN BAR

CALL 1 - 800 / KEATING

1

1

1

1

1

2

17

BURNER SPACER

18 AND ABOVE

019683

4

4

5

6

18

FRYER VESSEL

CALL 1 - 800 / KEATING

1

1

1

1

1

1

19

DRAIN VALVE, FRONT, 1”

AA, BB, TS, CMG

004553

1

1

DRAIN VALVE, REAR, 1”

AA, BB, TS

016341

1

1

DRAIN VALVE, FRONT, 1 1/4”

AA, BB, TS

004554

1

1

1

2

DRAIN VALVE, REAR 1/1/4”

AA, BB, TS

016342

1

1

1

2

20

DOOR CATCH, ROLLER STYLE

AA, BB, TS, CMG

004540

1

1

1

1

1

2

21

DRIP CUP (INSIDE DOOR)

AA, BB, TS, CMG

004552

1

1

1

1

2

22

HI-LIMIT CONTROL W/RESET

AA, BB, TS, CMG

SEE PAGES 18-20

23

THERMOSTAT

SEE MODEL

SEE PAGES 18-20

24

BASKET HANGER MOUNTING BLOCK

AA, BB, TS, CMG
LEFT

004539

1

1

1

1

1

1

CENTER

003813

1

1

1

2

RIGHT

004538

1

1

1

1

1

1

25

BASKET HANGER ROD

AA, BB, TS, CMG

SEE BELOW 2

2

2

2

2

2

26

MAIN SUPPLY GAS VALVE

BB, TS, CMG

019515

1

1

1

1

1

1

18-20 AA
10x11, 14 AA

019514

1

1

ITEM

DESCRIPTION

MODELS

10x11

14

18

20

24

34x24

25

BASKET HANGER ROD

2/FRYER

003849

003895

003935

003953

003954

011954

*Includes Items 6-9.

Summary of Contents for INSTANT RECOVERY

Page 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 715 S 25th AVENUEl BELLWOOD ILLINOIS l 60104 l 1 800 KEATING...

Page 2: ...nce 9 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 10 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Page 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Page 4: ...s l You must maintain the following minimum clearances from combustible and noncombustible construction l You must install this appliance at least 16 inches away from any open flame l Adequate clearan...

Page 5: ...DEFECTS OR OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keat...

Page 6: ...rrent ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS RE...

Page 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Page 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Page 9: ...NG PROCEDURES n USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL n CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER...

Page 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Page 11: ...er to a secure area to prevent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNE...

Page 12: ...OR The BEEPER will BEEP 4 times If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more STEP 2 PRESS all 3 buttons in sequence left center...

Page 13: ...thermostat bulb positioning Keating s patented thermostat application is accurate within 2 F of the dial setting between 250 F 350 F This accuracy is attained only if the thermostat bulb is placed pro...

Page 14: ...r 14 fryers 6 Refill fryer with oil to fill level line 7 Start fryer preheat and calibrate with thermometer D Hi Limit Check The manual Hi Limit test button can be used to test the Hi Limit Control by...

Page 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Page 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Page 17: ...ILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIGHT 004142 1 1 2 2 2 3 9 RUNNER PILOT...

Page 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Page 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Page 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Page 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Page 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Page 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Page 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Page 25: ...the inside of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer...

Page 26: ...23...

Page 27: ...24...

Page 28: ......

Page 29: ...____________ DEALER ________________________________________________________________________________________________________________ DATE OF PURCHASE __________________________________________________...

Reviews: