Water always filling.
a.Clean sensors thoroughly with brush and vinegar.
b.Adjust the sensitivity of the B Board (for the top sensor) fully clockwise.
c. If filling persists, ground out the top sensor (if filling stops, replace sensor –
Part #010212).
d.If filling persists after grounding out the sensor, replace the B Board (Part
#001166)
Water never fills.
a.Turn water switch (far right) ‘ON.’
b.Clean sensors thoroughly with brush and vinegar.
c. Adjust the sensitivity of the B Board (for the top sensor) fully
counterclockwise (follow instructions on sheet).
d.Remove the wire from the top sensor. If filling begins, replace the sensor
(Part #010212).
e.If water does not fill, place a jumper wire across terminals A & C on the B
Board. If filling begins, replace B Board (Part #001166).
f. If water does not fill, replace water solenoid (Part #008133).
Runner bar will not light.
a.Remove and clean the flame switch bulb in the runner bar, enabling it to get
red hot.
b. Reposition flame switch bulb in the runner bar, enabling it to get red hot.
c. Replace flame switch (Part #004311)
Timers counting down in the
wrong mode (Not minutes and
seconds).
a.Reset the timer (see instructions on page 9)
Water leaking in the rear of the
Custom Pasta System.
a.Replace fill hose (Part #033495 – Sold per foot)
Burners won't come on (gas
runner bar may be lit).
a.Verify operating instructions in this manual (See page 9)
b.Clean the sensors with brush and vinegar.
c. Adjust sensitivity of the A Board (for the lower sensor) fully
counterclockwise (follow instruction sheet).
d.Place the wire attached to the lower sensor to ground. If heating begins,
replace the sensor (Part #010212).
e.If heating does not begin, place a jumper wire across terminals A & C on
the A Board. If heating begins, replace the A Board (Part #001167).
Unit is out of power.
a.Check electrical connection.
b.Check fuses.
c. Check Hi-Limit control.
Unit is powered, runner bar
cannot be started.
a.Check gas connection.
b.Check the gas valve.
c. Check the spark ignition electrode and spark ignition module if there is no
spark on the electrode.
Runner tube is starting, but
cannot hold the flame.
a.Clean flame sensor switch.
b.Check electrical connection to the flame switch.
c. (spark ignition only) Check spark ignition electrode.